Problem
Possible Cause
Remedy
[] Abnormal noise.
a) Gear Motor or Gear 
Head
. Bearing worn out.
. Replace.
b) Auger Mechanism
. Bad alignment of 
auger.
. Realign.
. Foreign matter 
interrupting agitator.
. Remove foreign matter.
c) Dispense Water 
Solenoid
. Vibration due to 
loosening screws.
. Apply thread sealant to 
the parts and tighten.
[3] No water dispensed. a) Power Supply
. "OFF" position.
. Move to "ON" position.
b) Water Supply
. Water supply off or 
pressure too low.
. Check and get 
recommended pressure.
c) Dispensing Water 
Valve
. Coil winding open.
. Replace.
. Wiring to dispensing 
water valve.
. Check for loose or open 
connection. Repair or 
replace.
d) Control Board
. Defective.
. See "II.D.4. Control 
Board Check Procedure."
e) Water Dispense Switch . Opti Serve sensor 
defective. (OS only)
. See "5. Opti Serve (OS) 
Sensors."
. Bad contacts. (push 
button only)
. Check for continuity and 
replace.
5. Opti Serve (OS) Sensors
Be sure to check all items in section "IV.C.4. Dipsensing" prior to using this chart. Use 
the following charts along with the wiring diagram to troubleshoot the OS sensors. 
Problem
Possible Cause
Remedy
[] No ice dispensed.
a) OS Sensor 
. Dirty sensor.
. Clean, using Scale Away 
(6 fl. oz. (0.8 l) per  gal. 
(3.8 l) of water) or other 
non-abrasive cleaner.
. Defective.
. See chart 5a and 5b 
below.
b) Dispense Mode Switch  . Wrong setting.
. Move to desired setting.
. Bad contacts.
. Check for continuity and 
replace.
3. Loose connection.
3. Tighten.
c) Control Board
. Loose connection.
. Tighten.
. Defective.
. See "II.D.4. Control 
Board Check Procedure" 
and chart 5a and 5b 
below.