Hoshizaki DCM-750BWH(-OS) Manuale Supplementare

Pagina di 69
64
1. Water System
a) Cleaning Solution
Dilute 9.6 fl. oz. (0.9 l) of recommended cleaner, Hoshizaki "Scale Away" or "LIME-A-
WAY" (Economics Laboratory, Inc.), with .6 gal. (6.0 l) of warm water.
b) Cleaning Procedure
) Close the water supply line shut-off valve.
) Move the dispense mode switch to the "CONTINUOUS" position, then dispense all of 
the ice from the storage bin.
3) Move the control switch to the "DRAIN" position and allow the water system to drain for 
5 minutes.
Note: If the unit is running, the drain valve will not open until .5 minutes after the 
control switch is moved to the "DRAIN" position. This allows the components to 
cycle down.
4) Move the control switch to the "OFF" position, then turn off the power supply. Remove 
the front and top panels, then move the power switch to the "OFF" position.
5) Remove the front cover of the storage bin. Remove spout B, then remove spout A. See 
Fig. 6.
6) Pour the cleaning solution over the extruding head until the evaporator assembly and 
the reservoir are full and the solution starts to overflow into the drain pan.
Note: If there is excess scale on the extruding head, fill the evaporator assembly and 
reservoir as described above, then use a clamp on the reservoir hose between 
the reservoir and evaporator assembly to block flow. Pour additional cleaning 
fluid over the extruding head until the evaporator assembly is completely full.
7) Replace spout A, spout B, and the front cover of the storage bin in their correct 
positions.
8) Allow the icemaker to sit for about 0 minutes before operation. If you placed a clamp 
on the reservoir hose in step 6, remove it before operation.
9) Move the power switch to the "ON" position and replace the panels in their correct 
positions. Turn on the power supply, then move the control switch to the "ICE" position. 
Make ice using the solution until the icemaker stops making ice.
Note: This unit will not run without the front panel in position.
0) Move the control switch to the "DRAIN" position and allow the solution to drain for 
5 minutes.
) Move the control switch to the "ICE" position. Open the water supply line shut-off valve 
to supply water to the reservoir.
) After the gear motor starts, move the control switch to the "DRAIN" position and allow 
the water system to drain for 5 minutes.
Note: If you do not sanitize the unit, move the control switch to the "ICE" position after 
the water system drains. Allow the icemaker to run for about 30 minutes, then 
move the control switch to the "OFF" position. Turn off the power supply, then 
remove the front panel and front cover of the storage bin. Go to step  in "VI.
A..c) Cleaning and Sanitizing Procedure."