CAUTION:  Sharp  edges,  use  protective  gloves  when  
installing.
Tools Needed for Installation:
Sheet metal snips
5/16” nut driver
Phillips head screwdriver - #2
High temperature sealant or furnace cement rated for continuous 
use at 1,000
o
F minimum
Measuring tape
Parts Verification
See parts list on page 28 to verify components included in this vent 
kit prior to installation.
NOTE: If installing onto wood, lap, or vinyl siding, the vinyl siding 
kit should be used (sold separately, part number DV-822).
The vinyl siding vent kit, DV-822, is available from Empire Comfort 
Systems, Inc. The depth is 3” (76 mm), which enables the vent cap 
to be extended away from vinyl siding or projections. The wall depth 
plus the additional 3” (76 mm) depth of the vinyl siding vent cap 
extension should not exceed a total depth of 13 3/4” (349 mm).
If  wall  depth  exceeds  13  3/4”  (349  mm),  extend  system  using  
6 5/8” (168 mm) x 4” (102 mm) rigid venting (See Fireplace In-
structions for approved lengths) See Figure 38.
Installing Wall Thimble/Firestop Assembly
1.  Fix fireplace to permanent location. If using rigid venting sys-
tem, install up to the location where it will exit the building.
2.  Cut hole in wall for wall thimble/firestop assembly into your 
combustible wall.  See Figure 37. Note: On brick or block 
exterior wall a 7” (178 mm) diameter hole needs to be cut. 
 
Measure the total wall thickness to determine whether or not 
the extension thimble is to be used.  If the combustible wall 
depth is over 5 3/8” (137 mm), then the extension thimble 
should be used. See Figure 37.
3.  Install  the  wall  thimble  assembly  through  the  framed 
opening  so  the  firestop  plate  is  on  the  interior  wall.  See  
Figure 37.  Telescope section should extend all the way through 
the exterior wall. Attach with (4) 10 x 1” screws.
4.  When placing the vent cap on an exterior wall covered with 
combustibles such as wood, lap, or vinyl siding, install the  
vinyl siding kit to the exterior wall sheathing.
Figure 37
Figure 38
Cutting Vent Tubes
This is the most important part of the installation.
  With the 
fireplace (and the rigid venting system if used) fixed to its permanent 
location, the 6 5/8” (168 mm) diameter air inlet tube and the 4” 
(102 mm) diameter flue outlet tube are to be marked and cut using 
the following procedure.
5.  Attach  the  inlet  tube  to  the  outside  mounting  plate. Align  
tinnerman clips on the tabs of the air inlet tube to the holes on 
outside mounting plate, and fix with (2) #10 x 1/2” screws.
6.  With the vinyl siding kit installed to wall (if necessary), insert 
the 6 5/8” (168 mm) diameter tube with outside mounting plate 
attached through hole in wall. Connect to collar on fireplace or 
rigid vent system. Measure between wall or vent cap extension 
and outside mounting plate (Figures 39 and 40).
11”
9”
NOTE: SPACING FLANGE
INSTALLED TO TOPSIDE
INTERIOR WALL
EXTENSION
THIMBLE
DVVK-4RE VENT KIT INSTALLATION INSTRUCTIONS
X
X = 13 3/4” MAX
TOTAL WALL THICKNESS
(SUBTRACT 3” IF USING THE
DV822 VINYL SIDING KIT)
½” AIR SPACE
CLEARANCE