Empire Comfort Systems VFD26F3-1 Manuale Utente

Pagina di 32
Page 16
23466-0-0407
Replacement Loose Material 
(glowing embers) 
Part Number
Rock Wool
15998
Platinum Bright Embers
PE-20-1
Provided with the log set is a small bag of glowing embers (rock 
wool) to be placed between logs on the flat metal surface of the 
burner.
Placement of the embers (rock wool) is very individual and light 
coverage of the areas indicated will provide your best effects. We 
recommend separation of the rock wool by hand and make your 
coverage as light and fluffy as possible.
Place just enough embers (rock wool) on the burner to obtain the 
glow and a gold yellow flame.
Do not place rock wool over large ports in rear portion of burner.
A  thin  layer  of  rock  wool  should  be  placed  under  open  space 
between the front and middle logs.
Rock  wool  should  not  be  placed  in  the  area  of  the  pilot 
assembly.
Replacement of loose material (glowing embers) must be purchased 
from Empire Comfort Systems, Inc. Application of excess loose 
material (glowing embers) may adversely affect performance of 
the heater. 
WARNING: All previously applied loose material must be removed 
prior to reapplication.
Refer to Parts List, Page 26 to order loose material (rock wool).
Note: A single layer of embers is to be used when applying Platinum 
Bright Embers (alone or in combination with production embers) 
to the burner.
Flames from the pilot (rear right back side of the burner) as well 
as the main flame should be visually checked as the log set is 
installed.
In normal operation at full rate after 10 to 15 minutes, the flame 
appearance should be sets of yellow flames.
NOTE: All flames will be random by design, flame height will 
go up and down.
Glowing embers (rock wool) can cover the burner in between the 
front and middle logs, but very little is necessary to cover this 
area. Excess ember material causes the yellow flame to become 
orange and stringy. Apply just enough to obtain slow glow and a 
gold, yellow flame.
Avoid any drafts that alter burner flame patterns. Do not allow fans 
to blow directly into fireplace. Do not place a blower inside the 
burner area of the firebox. Ceiling fans may create drafts that alter 
flame patterns. Sooting and improper burning will result.
During  manufacturing,  fabricating  and  shipping,  various 
components of this appliance are treated with certain oils, films or 
bonding agents. These chemicals are not harmful, but may produce 
annoying smoke and smells as they are burned off during the initial 
operation of the appliance, possibly causing headaches or eye or 
lung irritation. This is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner 
at the highest setting. Provide maximum ventilation by opening 
windows or doors to allow odors to dissipate. Any odors remaining 
after this initial break-in will be slight and will disappear with 
continued use.
PLACEMENT OF GLOWING EMBERS (ROCK WOOL)
OPERATION INSTRUCTIONS/FLAME APPEARANCE
Figure 14