Empire Comfort Systems VFD26F3-1 Manuale Utente

Pagina di 32
Page 20
23466-0-0407
Figures 15 and 18 show a correct pilot flame pattern. The correct 
flame will be blue and will extend beyond the thermocouple. The 
flame will surround the thermocouple just below the tip. A slight 
yellow flame may occur where the pilot flame and main burner flame 
meet. Figures 16 and 19 show an incorrect pilot flame pattern. The 
incorrect pilot flame is not touching the thermocouple. This will 
cause the thermocouple to cool. When the thermocouple cools, the 
heater will shut down.
(A)VFD26F(M,P)3 PILOT
Correct Pilot Flame Pattern
Figure 15
Incorrect Pilot Flame Pattern
Figure 16
If pilot flame pattern is incorrect, as shown in Figure 15
•  See Troubleshooting, page 25.
Cleaning and Maintenance/Pilot
Oxygen Depletion Sensor Pilot
When the pilot has a large yellow tip flame, clean the Oxygen 
Depletion Sensor as follows:
1.  Clean the ODS pilot by loosening nut B from the pilot tubing. 
When this procedure is required, grasp nut A with an open end 
wrench.
2.  Blow air pressure through the holes indicated by the arrows. 
This will blow out foreign materials such as dust, lint and spider 
webs. Tighten nut B also by grasping nut A. 
Warning: 
Never use needles, wires, or similar cylindrical objects to 
clean the pilot to avoid damaging the calibrated ruby that 
controls the gas flow.
Figure 17
(A)VFD26F(M,P)2 PILOT
Correct Pilot Flame Pattern
Figure 18
Incorrect Pilot Flame Pattern
Figure 19
If pilot flame pattern is incorrect, as shown in Figure 19
•  See Troubleshooting, page 25.
PILOT FLAME CHARACTERISTICS