Jotul GF 100 DV II Manuale Utente

Pagina di 32
14
GF 100 DV II Nordic QT
GF 200 DV II Lillehammer
Figure 17.  Vent Terminal Clearances - National Fuel Gas Code.
Horizontal Termination Clearance
A = Clearance above grade, veranda, porch , deck, or
balcony : 12 inches (30 cm) minimum.
B = Clearance to window or door that may be opened:
**Min. 9 inches, U.S. /  *12 inches (30 cm) CAN.
We recommend 12in. minimum to prevent condensa-
tion on the window.
C = Clearance to permanently closed window:
**Min. 9 inches, U.S. /  *12 inches (30 cm) CAN
We recommend 12 in. minimum to prevent condensa-
tion on the window.
D = Vertical clearance to ventilated soffit located above
the terminal within a horizontal distance of 2 feet (60 cm)
from the centerline of the terminal: 18 inches
(46 cm) minimum.
= Clearance to unventilated soffit:  12 inches (46 cm)
minimum.
= Clearance to outside corner: **Min. 9 inches, U.S. /  *12
inches (30 cm) CAN. We strongly recommend 12 inches,
particularly where windy conditions pevail.
G = Clearance to inside corner:  ** Min. 6 inches, U.S. /  *12
inches (30 cm) CAN. We strongly recommend 12 inches,
particularly where windy conditions pevail.
H = *Not to be installed within 15 feet (4.5 m) above a
meter/regulator assembly within 3 feet (90 cm)
horizontally from the center-line of the regulator.
* In accordance with CSA B149.1 Installation Codes.
**    In accordance with the current ANSI Z223.1/NFFPA 54,
National Fuel Gas Code. Note: Local Codes and Regulations may
require different clearances.
1
 A vent shall not terminate directly above a sidewalk or driveway
which is located between two single family dwellings and serves
both dwellings.
2
Only permitted if veranda, porch, deck, or balcony, is fully open
on a minimum of two sides beneath the floor.*
I = Clearance to service regulator vent outlet:
3 feet  (91 cm) minimum.
= Clearance to nonmechanical air supply inlet to building or
the combustion air inlet to any other appliance:
12 inches (30 cm) minimum.
= Clearance to a mechanical air supply inlet:
**Min. 3 feet (91 cm) above if within 10 feet horizontally,
U.S. /  *6 feet (1.83 m) minimum / CAN
L = 
1
 Clearance above paved sidewalk or a paved driveway
located on public property: 7 feet (2.1 m) min.
M = Clearance under veranda, porch, deck, or balcony:
12 inches (30 cm) minimum.
 2