Desa CGCDV42NR Manuale Utente

Pagina di 44
www.desatech.com
116236-01E
37
REPLACEMENT PARTS
Note
Use only original replacement parts. This 
will protect your warranty  coverage  for  parts 
replaced under warranty. 
PARTS UNDER WARRANTY
Contact authorized retailers of this product. If 
they can not supply original replacement part(s), 
call DESA’s Customer Service Department at 
1-866-672-6040.
When calling DESA, have ready
•  your name
•  your address
•  model and serial numbers of your fireplace 
•  how fireplace was malfunctioning
•  type of gas used (propane/LP or natural gas)
•  purchase date
Usually, we will ask you to return the part to the 
factory.
PARTS NOT UNDER WARRANTY
Contact authorized retailers of this product. If 
they can not supply original replacement part(s), 
call DESA at 1-866-672-6040 for referral infor-
mation.
When calling DESA, have ready
•  model number of your fireplace 
•  the replacement part number
SERVICE hINTS
When Gas Pressure Is Too Low
•  pilot will not stay lit
•  burners will have delayed ignition
•  fireplace will not produce specified heat
•  propane/LP gas supply might be low (propane/
LP units only)
You may feel your gas pressure is too low. If so, 
contact your local gas supplier.
TEChNICAL SERVICE
You may have further questions about installation, 
operation or troubleshooting. If so, contact DESA’s 
Customer Service Department at 1-866-672-6040. 
When calling, please have your model and serial 
numbers of your heater ready.
You can also visit DESA’s technical service web site at 
www.desatech.com
.
SPECIFICATIONS
VC42N, VVC42N AND CGCDV42NR
•  Rating: 25,000/36,000 Btu/hr
•  Gas Type: Natural Gas Only
•  Ignition: Piezo
•  Manifold Pressure: 3.5" w.c.
•  Minimum Inlet Supply Pressure: 5.5" w.c.
•  Firebox Dimensions (HxWxD) (Flanges and 
Standoffs  Not  Included  in  Measurement): 
40" x 48" x 23 
1
/
2
" (1016 x 1219 x 599 mm)
VC42P, VVC42P AND CGCDV42PR
•  Rating: 23,000/33,000 Btu/hr
•  Gas Type: Propane/LP Gas Only
•  Ignition: Piezo
•  Manifold Pressure: 10.0" w.c.
•  Minimum Inlet Supply Pressure: 11.0" w.c.
•  Firebox Dimensions (HxWxD) (Flanges and 
Standoffs  Not  Included  in  Measurement): 
40" x 48" x 23 
1
/
2
" (1016 x 1219 x 599 mm)
VC42N-HA, VVC42N-HA AND 
CGCDV42NR-HA
•  Rating: 25,000/36,000 Btu/hr
•  Gas Type: Natural Gas Only
•  Ignition: Piezo
•  Manifold Pressure: 3.8" w.c.
•  Minimum Inlet Supply Pressure: 5.5" w.c.
•  Firebox Dimensions (HxWxD) (Flanges and 
Standoffs  Not  Included  in  Measurement):
40" x 48" x 23 
1
/
2
" (1016 x 1219 x 599 mm)