Desa CGCFTN Manuale Utente

Pagina di 32
www.desatech.com
111044-01J
16
INSTALLATION
Continued 
CONNECTING EQUIPMENT 
SHUTOFF VALVE TO HEATER 
CONTROL
Installation Items Needed
•  Phillips screwdriver
•  sealant  (resistant  to  propane/LP  gas,  not 
provided)
1.  Remove fireplace screen. Remove two screws 
that hold fireplace screen in place for shipping. 
These screws are located near top of screen. 
Discard screws. Lift fireplace screen up and 
pull out to remove.
2.  Remove screws that attach branch support 
to fireplace (see Figure 20). Carefully lift up 
branch support and remove from fireplace (see 
Figure 20).
3.  Route flexible gas line, included, from fireplace 
control to equipment shutoff valve through side 
or rear access holes in outer casing.
NOTICE:  Most  building  codes 
do  not  permit  concealed  gas 
connections. A flexible gas line 
is provided to allow accessibility 
from the fireplace (see Figure 21). 
The flexible gas supply line con-
nection to the equipment shutoff 
valve should be accessible.
 CAUTION: Avoid damage to 
regulator.  Hold  gas  regulator 
with wrench when connecting it 
to gas piping and/or fittings.
4.  Apply pipe joint sealant lightly to male threads 
of gas connector attached to flexible gas line/
equipment shutoff valve (see Figure 21).
5.  Check  all  gas  connections  for  leaks.  See 
Checking Gas Connections.
6.  Replace branch support back into fireplace. 
Feed flexible gas line into fireplace base area 
while replacing branch support. Make sure 
the entire flexible gas line is in fireplace base 
area. Reattach branch support to fireplace with 
screws removed in step 2.
Figure 20 - Removing Log Base 
Assembly From Fireplace
Branch 
Support
Screen
Screen 
Shipping 
Screw
Shoulder 
Screw
Flexible 
Gas Line
Figure 21 - Attaching Flexible Gas Line 
to Equipment Shutoff Valve
Flexible Gas Line from 
Fireplace Gas Regulator
Provided with Fireplace
To Fireplace 
Gas Regulator
Equipment Shutoff 
Valve Provided by 
Installer
CHECKING GAS CONNECTIONS
 WARNING: Test all gas piping 
and  connections,  internal  and 
external to unit, for leaks after 
installing or servicing. Correct 
all leaks at once.
  WARNING:  Never  use  an 
open flame to check for a leak. 
Apply a noncorrosive leak detec-
tion fluid to all joints. bubbles 
forming show a leak. Correct all 
leaks at once.
PROPANE/LP
To External 
Regulator
 
NATURAL
To Gas Supply