Desa CGCFTN Manuale Utente

Pagina di 32
www.desatech.com
111044-01J
1
OPERATING FIREPLACE
Continued
6.  With control knob pressed in, push down 
and release ignitor button. This will light 
pilot. The pilot is attached to the front of 
burner. If needed, keep pressing ignitor 
button until pilot lights.
  Note:  If  pilot  does  not  stay  lit,  refer  to 
Troubleshooting, page 22. Also contact a 
qualified service person or gas supplier for 
repairs. Until repairs are made, light pilot 
with match. To light pilot with match, see 
Manual Lighting Procedure.
7.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control knob.
  Note:  If  pilot  goes  out,  repeat  steps  3 
through 7. This fireplace has a safety in-
terlock system. Wait one (1) minute before 
lighting pilot again.
8.  Turn control knob counterclockwise 
 
to desired heating level. The main burner 
should light. Set control knob to any heat 
level between HI and LO.
 CAUTION: Do not try to ad-
just heating levels by using the 
equipment shutoff valve.
Thermocouple
Pilot Burner
Figure 26 - Pilot
Ignitor 
Electrode
TO TURN OFF GAS 
TO APPLIANCE
Shutting Off Fireplace
1.  Turn control knob clockwise 
 to the 
OFF position.
2.  Turn off all electric power to the appliance 
if service is to be performed.
Shutting Off burner Only (pilot stays lit)
Turn control knob clockwise 
 to the PI-
LOT position.
THERMOSTAT  
CONTROL OPERATION
The thermostatic control used on this fireplace 
differs from standard thermostats. Standard 
thermostats simply turn on and off the burner. 
The thermostat used on this fireplace senses the 
room temperature. The thermostat adjusts the 
amount of gas flow to the burner. This increases 
or decreases the burner flame height. At times 
the heater will cycle back on when room tem-
perature drops below the set temperature.
The control knob can be set to any heat level 
between HI and LO.
Note:
 
The thermostat sensing bulb measures 
the  temperature  of  air  near  the  fireplace 
cabinet.  This  may  not  always  agree  with 
room  temperature  (depending  on  housing 
construction, installation location, room size, 
open air temperatures, etc.). Frequent use of 
your fireplace will let you determine your own 
comfort levels.
MANUAL LIGHTING 
PROCEDURE
1.  Follow steps 1 through 5 under Lighting 
Instructions, page 18.
2.  With control knob pressed in, strike match. 
Hold match to pilot until pilot lights. 
3.  Keep control knob pressed in for 30 seconds 
after lighting pilot. After 30 seconds, release 
control  knob.  Now  follow  step  8  under 
Lighting Instructions, column 1.