4. Configuration Options
4-50
  
September 
2002
9128-A2-GB20-80
Outbound Phone Number
Possible Settings: 0 – 9*#, space, ,  , (, or )
Default Setting: none
Specifies the primary phone number to call (the ISDN Called Party Identifier) for the Link 
Profile. Up to 18 valid characters can be entered. Each Outbound Phone Number must be 
unique. If not, the 
Outbound Phone Number is Not Unique
 message appears and 
you must enter another phone number.
NOTE:  For every originating (outbound) phone number entered, an answering 
(inbound) phone number must be entered at the far end, and vice versa.
Currently active calls are not effected when this number is changed.
Inbound Calling ID 1 or 2
Possible Settings: 0 – 9
Default Setting: none
Specifies the local phone number of a remote device from which that the unit will accept 
calls (the ISDN Calling Party Identifier). Up to 18 digits can be entered. Each Inbound 
Calling ID must be unique. If not, the 
Inbound Calling ID 
n is Not Unique
 
message appears and you must enter another phone number.
For remote devices with a PRI DBM, only one Inbound Calling ID is required. Inbound 
Calling ID 2 is provided to identify incoming calls from a second phone number assigned 
to a remote device with a BRI DBM.
NOTES:
– Inbound Calling ID 2 is only useful when multiple local phone numbers are 
programmed at the originating site (e.g., a 2B+D BRI location).
– For every originating (outbound) phone number entered, an answering (inbound) 
phone number must be entered at the far end, and vice versa.
Currently active calls are not effected when this number is changed.
0 – 9 – Specifies the numbers in the remote device’s local phone number.
Maximum Link Rate (Kbps) 
Possible Settings:
For a BRI DBM: 64128
For a PRI DBM: 64 – 1472
Default Setting: 64
Specifies the maximum rate that will be attempted for the frame relay link when it is 
activated. The actual rate achieved on the link depends upon the number of successful 
calls placed or answered, and the negotiated rate on each call.
NOTE:  This option takes effect as soon as a change is saved. If the rate is increased, 
additional calls will be placed. If the rate is decreased, calls will be dropped. For extra 
calls to be successful, the Maximum Link Rate must be increased at the originating 
device before it is increased at the answering device.
64 – An individual frame relay link is formed and a single call is placed using a B-channel 
when the link is activated.
128 . . . 1472 – A constituent link is configured for each multiple of 64 Kbps in the 
specified bandwidth. This bundle of constituent links will function as a single frame relay 
multilink. When the multilink aggregate link is activated, calls will be placed or answered 
on as many constituent links as possible based upon available B-channels.
Table 4-11. ISDN Link Profile Options (2 of 3)