LOCAL CODES
Install and use fireplace with care. Follow all local 
codes. In the absence to local codes, use the cur-
rent National Fuel Gas Code ANSI Z223.1/NFPA 
54* (USA) or the current CSA-B149.1 Installation 
Code (Canada).
*Available from:
American National Standards Institute, Inc.
1430 Broadway
New York, NY 10018
National Fire Protection Association, Inc.
Batterymarch Park
Quincy, MA 02269
PRODUCT FEATURES
These are a few facts that can help you understand 
and enjoy your direct-vent fireplace:
•  The venting system may be routed to the out-
side of your home in several ways. It may vent 
through the roof (vertical) or it may vent to an 
outside/exterior wall (horizontal). The vent 
pipe installation is very important to allow for 
proper operation. You must follow the venting 
instructions very carefully for either vertical or 
horizontal applications.
•  This fireplace may be installed in any room of 
your house provided all local codes and these 
installation instructions are followed.
•  This fireplace requires a wall switch, hand-held 
remote or wall thermostat (millivolt) for opera-
tion (see Accessories, page 42).
•  This fireplace does not require electricity to 
operate.
•  Only the blower requires electricity if installed 
and if you plan to install the blower at a later 
date, do not forget to wire the outlet at the bot-
tom of the fireplace when framing.
•  A piezo ignitor and ceramic electrode create 
spark to ignite the pilot light. It does not require 
any matches, batteries or any other sources of 
ignition to light the pilot.
•  Each time you turn on your fireplace, you may 
notice some amount of condensation on the in-
side of the fireplace glass. This is normal and will 
disappear after 10-20 minutes of operation.
•  Your direct-vent gas fireplace system (fireplace 
and venting) is a balanced and sealed gas op-
erating unit. It requires approximately 10-20 
minutes of operating time before the flame 
pattern stabilizes.
•  Fireplaces with the suffix of -HA have been 
designed to operate at altitudes of 4000 feet 
and above.
Figure 2 - Common Fireplace Locations
Flush with a wall
Through exterior wall 
enclosed in a chase
Corner 
installation
Figure 3 - Fireplace Bottom Dimensions
D
RW
FW
23 
1
/
4
"
36 
1
/
4
"
48"
PRE-INSTALLATION 
PREPARATION
LOCATION AND SPACE 
REqUIREMENTS
Determine the safest and most efficient location 
for your DESA direct-vent fireplace. Make sure 
that rafters and wall studs are not in the way of the 
venting system. Choose a location where the heat 
output is not affected by drafts, air conditioning 
ducts, windows or doors. Figure 2 shows some 
common locations. Be aware of all restrictions and 
precautions before deciding the exact location for 
your fireplace and termination cap.
When deciding the location of your fireplace, 
follow these rules:
•  Do not connect this fireplace venting to a chim-
ney flue serving a separate solid-fuel burning 
fireplace or appliance.
•  Due to high temperatures, do not locate this 
fireplace in high traffic areas, windy or drafty 
areas or near furniture or draperies.
•  Proper clearances must be maintained.
•  If your fireplace is to be installed directly on 
carpeting, vinyl tile or any combustible mate-
rial other than wood, it must be installed on a 
metal or wood panel extending the full width 
and depth of the fireplace. See Figure 3.