TROUBLESHOOTING 
 
 
 
 
 
 
Note: Before trouble shooting the system, make sure the power 
to the circuit from the breaker or fuse panel is turned ON. 
The three most common causes of a malfunctioning heater are: 
 
1.  Tripped circuit breaker or blown fuse. 
 
2.  Loose or burned out light bulb. 
 
3.  Obstructed or clogged fan blower. 
 
 
OBSERVED PROBLEM 
 
No operation or indicator light at 
power/ heater switch. 
 
 
  
 
 
 
 
 
Poor flame motion; flame pattern is 
sporadic or devoid in viewing area. 
 
 
 
 
 
 
 
 
 
 
 
Dull flame appearance or inactive 
ember bed effect. 
 
 
 
 
 
 
 
 
 
 
No heat or intermittent heat output. 
(If equipped with a heater)  
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
POSSIBLE CAUSE 
 
 
1.  No power to appliance. 
 
2. Defector switch lamp. 
 
3. Defective wiring. 
 
 
 
 
1.  Tangled or loose flame pennants. 
 
 
 
2.  Obstructed or clogged fan blower. 
 
 
   
 
 
3.  Damaged or dislodged fan blower wheel.  
 
 
 
1.  Burned out or loose light bulb.   
 
 
 
 
 
2.  Broken lamp fixture. 
 
 
3.  Loose or missing reflective ribbons. 
 
 
 
1. Obstructed heater blower. 
 
 
 
 
2.  Burned out heat element or blower fan.  
 
 
 
3.  Defective heater switch or wiring. 
 
 
 
 
 
 
 
 
 
REMEDY 
 
 
1.  Check circuit breaker or fuse. 
 
2.  Replace defective switch. See Servicing 
Control Panel, page 14
 
3.  Check connections from main power 
harnesses to terminals on control panel. 
See Servicing Control Panel, page 14
 
1.  Inspect flame pennants untangle or 
replace if necessary. See Servicing Flame 
Pennants, 
page 17
  
2.  Check fan blower for debris; vacuum 
areas around blower wheel and remove 
any obstructions. See Maintaining 
Motors
, page 13
 
 
3.  Remove and inspect fan blower housing 
See Servicing Fan Blower, page 16
 
 
1. Inspect light bulbs; tighten or replace 
light bulbs as necessary. See Replacing 
Light Bulbs
, page 13
 
2.  Remove and replace broken lamp fixture. 
See Replacing Lamp Fixtures, page 17
 
3.  Inspect reflective ribbons; Reattach or 
replace as necessary. See Replacing 
Reflective Ribbons
, page 18
 
1.  Clear heater fan of debris or blockage; 
vacuum area around blower intake and 
remove any obstructions in the discharge 
area. See Maintaining Motors, page 13
 
2.  Remove and replace blower heater 
assembly. To access and remove see 
Optional Heater Accessory, page 8.  
 
3.  Inspect wiring connections from switch 
to blower. Replace switch if defective. 
See Servicing Control Panel, page 14
 
 
 
 
11 
Note: For additional help, visit DESA Technical Service web 
site at www.desatech.com 
F
F
o
o
r
r
 
 
m
m
o
o
r
r
e
e
 
 
i
i
n
n
f
f
o
o
r
r
m
m
a
a
t
t
i
i
o
o
n
n
,
,
 
 
v
v
i
i
s
s
i
i
t
t
 
 
w
w
w
w
w
w
.
.
d
d
e
e
s
s
a
a
t
t
e
e
c
c
h
h
.
.
c
c
o
o
m
m
 
 
111076-01C