Dansons Group FPP Manuale Utente

Pagina di 40
 
Can
adian Comfort Industries      V04                                            
34                                                        
 PELPRO OWNERS MANUAL 
Copyright 2004                                                                     
www.pelprostoves.com
                                                        
Dansons Group Inc.
 
P
ERIODIC 
M
AINTENANCE
   
 CONTINUED
 
 
INSPECT AND CLEAN THE CHIMNEY:
  [ELECTRICAL CORD UNPLUGGED] Under some 
conditions fly ash build up in the chimney system may occur rapidly.  The fly ash will collect in the exhaust 
venting system and restrict the flow of the flue gases.  Incomplete combustion, such as occurs during 
startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which will 
collect in the exhaust venting system.  Check the clean out tees and elbows in the exhaust system 
periodically to determine the cleaning schedule.  To remove dust from the vent pipe, tap lightly on the pipe to 
dislodge any loose ash.  Open the bottom of the “T” to dump the ash, then vacuum as much of the ash out of 
the vent pipe as possible.  3 or 4-inch chimney brushes are available for chimney cleaning.  If the exhaust 
system has a screen on it, frequently clean the screen. A plugged screen will shut off combustion air and 
cause a fire to die or burn poorly. 
 
PAINTED SURFACES:
 Painted surfaces may be wiped down with a damp cloth. If scratches appear or 
you wish to renew your paint, contact your Dealer to obtain a can of Satin Black (“Stove Bright”) paint. 
 
Tip: use a hair dryer to warm the surface prior to touching up the paint, 
 this helps to reduce paint runs. 
Note: Do not use any other brand than “Stove Bright” as they may not be compatible. 
 
 
FALL START UP:
  Prior to lighting the first fire check the outside area around the exhaust and air intake 
systems for obstructions.  Clean the screens on the exhaust system and the outside air intake pipe.  Turn all 
controls on to make sure they are working prior to lighting the first fire. Clean and remove fly ash from 
exhaust venting.  Your local Authorized Dealer should have 3” and 4” chimney brushes available.  This is 
also a good time to give the entire stove a good cleaning throughout.   
 
 
SPRING SHUTDOWN:
  [COLD STOVE AND COLD ASHES ONLY].  After the last burn in the spring 
remove pellets from the hopper and the auger.  Scoop out the pellets then run the auger until the hopper is 
empty and pellets stop flowing.  Vacuum out the hopper.  Thoroughly clean the burn grate, burn box, ashtray 
and ash traps.  It’s desirable to spray the inside of the cleaned hopper with an aerosol silicone spray if your 
stove is in a high humidity area.  The 
exhaust system should be thoroughly cleaned.   
 
 
YEARLY SERVICING:
  A yearly servicing and cleaning by your Authorized PELPRO
 
Dealer   is 
recommended.  A fee may be charged for this service. 
 
 
Figure 30 
 
 
 
 
 
 
 
 
Window
Burn Pot
Burn Grate
Heat Tubes
Tube Scraper
E Z Clean
Grate
Hopper
Fan Motors
Auger
Exhaust
Air Intake
Auger Motor
Ash Pan