Lexmark X644e Guida Utente

Pagina di 416
PostScript
4-72
 
Table 4-11:  PostScript Emulation Device Parameters
Key
Type
Definition 
Device Parameters for the Communication Device %Parallel%, %ParallelA%, %ParallelB%, %ParallelC%, %ParallelD%
(%Parallel_NV% and %Parallel_Pending% contain the same parameters)
DelayedOutputClose
boolean
Selects how the printer manages the port at the end of each print job. Supported values are:
True
An end-of-file message is not sent until the current job and all preceding jobs 
finish printing.
False
An end-of-file message is sent as soon as a job finishes executing in the 
interpreter, whether or not that job has finished printing.
This value is set independently for each port.
Enabled
boolean
(Read-only)
Supported values are:
True
False
Filtering
name
Indicates if the input needs further filtering before the data can be correctly processed. 
Supported values are:
InterpreterBased
None
Handshake
integer
(Read-only) Always returns a value of 2.
HasNames
boolean
(Read-only) Always returns False.
Interpreter
name
(Read-only)
Supported values are:
PostScript
AutoSelect
PCL
PPDS
On
boolean
Designates if the communication channel is On and able to receive and send data. 
Supported values are:
True
Data is sent and processed
False
Data is lost
OutputDevice
string
(Read-only)
PCLSmartSwitch
boolean
Supported values are:
True
PCL SmartSwitch
 is set to 
On
.
False
PCL SmartSwitch
 is set to 
Off
.
PortLocation
string
(Read-only) Designates the physical location of the port related to the parameter set. 
Supported values are:
Standard Port
Option Slot 1
Option Slot 2
Option Slot 3
Option Slot 4