Alcatel-Lucent 6850-48 Guida Di Rete

Pagina di 1162
Configuring 802.1AB
Configuring 802.1AB
page 19-8
OmniSwitch AOS Release 6 Network Configuration Guide
September 2009
Configuring 802.1AB
The following sections detail procedures for enabling 802.1AB and assigning ports to 802.1AB.
Configuring LLDPDU Flow
 command can be used to enable or disable the LLDPDU flow on a specific port, a slot, or 
all ports on a switch. When enabled, the port can be set to receive, transmit, or both transmit and receive 
LLDPDUs. 
To set the LLDPDU flow on a switch as transmit and receive, enter the lldp lldpdu command, as shown:
-> lldp chassis lldpdu tx-and-rx
To set the LLDPDU flow on port 4 of slot 3 as receive, enter the following command at the CLI prompt:
-> lldp 3/4 lldpdu rx
To disable the flow of LLDPDU on a switch, enter the lldp lldpdu command, as shown:
-> lldp chassis lldpdu disable
To disable the flow of LLDPDU on port 5 of slot 1, enter the following command at the CLI prompt:
-> lldp 1/5 lldpdu disable
Enabling and Disabling Notification
 command is used to control per port notification status about the remote device 
change on a specific port, a slot, or all ports on a switch. When enabled, the LLDPDU administrative 
status must be in the receive state.
To enable notification of local system MIB changes on a switch, enter the lldp notification command, as 
shown:
-> lldp chassis notification enable
To enable notification on port 2 of slot 1, enter the following command at the CLI prompt:
-> lldp 1/2 notification enable
To disable notification on a switch, enter the lldp notification command, as shown:
-> lldp chassis notification disable
To disable notification on port 4 of slot 1, enter the following command at the CLI prompt:
-> lldp 1/4 notificaition disable