Alcatel-Lucent 6850-48 Guida Di Riferimento

Pagina di 3444
AAA Commands
OmniSwitch CLI Reference Guide
September 2009
page 58-63
user lockout-threshold
Configures the number of failed password login attempts allowed during a certain period of time (observa-
tion window). If the number of failed attempts exceeds the lockout threshold number before the observa-
tion window period expires, the user account is locked out.
user lockout-threshold number
Syntax Definitions
number
The number of failed login attempts allowed. The range is 0 to 999.
Defaults
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E
Usage Guidelines
• This command is only available to the admin user because the admin user account is the only account 
protected from any type of lockout attempt. 
• If the lockout threshold is set to zero (the default), there is no limit to the number of failed login 
attempts allowed.
• A user account remains locked out for the length of the lockout duration time period; at the end of this 
time, the account is automatically unlocked. 
• If the lockout duration time period is set to zero, only the admin user or a user with read/write AAA 
privileges can unlock a locked user account. An account is unlocked by changing the user account 
password or with the 
• The lockout threshold time period is a global lockout setting that is applied to all passwords config-
ured on the switch.
• Lockout settings are saved automatically; that is, these settings do not require th
 command to save user settings over a reboot.
Examples
-> user lockout-threshold 3
-> user lockout-threshold 0 
Release History
Release 6.3.1; command was introduced.
parameter
default
number 
0