Alcatel-Lucent 6850-48 Guida Di Riferimento
Chassis Management and Monitoring Commands
page 2-14
OmniSwitch CLI Reference Guide
September 2009
update
Updates the versions of Uboot, FPGA, BootROM, or Miniboot. Refer to the Release Notes and/or any
available Upgrade Instructions for the new release before performing this type of update on the switch.
available Upgrade Instructions for the new release before performing this type of update on the switch.
update {uboot {cmm | ni {all | slot}} uboot-miniboot | fpga cmm | bootrom {all | slot} | [default |
backup] miniboot [all | slot] }
backup] miniboot [all | slot] }
Syntax Definitions
uboot
Updates the uboot version.
cmm
Specifies that the update is performed for the Chassis Management
Module (CMM). Not supported on OmniSwitch 6850 switches
Module (CMM). Not supported on OmniSwitch 6850 switches
ni
Specifies that the update is performed for the Network Interface (NI)
Module.
Module.
all
Specifies that the update is performed for all slots within a chassis or all
switches within a stack.
switches within a stack.
slot
Specifies the number of the NI module within a chassis or the switch
number within a stack for which the update is performed.
number within a stack for which the update is performed.
uboot-miniboot
Updates the uboot and the miniboot version on all available slots within
a chassis or on all available switches within a stack.
a chassis or on all available switches within a stack.
fpga
Updates the FPGA version. Not supported on OmniSwitch 6850
switches.
switches.
miniboot
Updates the miniboot version.
Defaults
N/A
Platforms Supported
OmniSwitch 6400, 6850, 6855, 9000, 9000E.
Usage Guidelines
• On OmniSwitch chassis-based switches, the slot parameter is not allowed with the cmm parameter.
• Note that when performing an update, it is important that the correct update file is used and that the file
is located in the /flash directory on the switch. Specifying the wrong file may impact the operation of
the switch.
the switch.
• A different update file is required depending on the type of switch and the type of update. The
following table provides a list of the required update files:
OmniSwitch
Update Type
Update File
6400
Uboot
kuboot.bin
Miniboot
gminiboot.uboot