Alcatel-Lucent 6850-48 Manuale Hardware

Pagina di 188
Managing OmniSwitch 6850 Series Stacks
Slot Numbering
OmniSwitch 6850 Series Hardware Users Guide
September 2009
page 4-23
When the stack comes up following the reboot, the manually-configured slot numbers display as follows:
The stack set slot command can also be used to manually correct duplicate saved slot assignments within 
the stack topology. Refer to page
 through 
 for detailed information.
Reverting to the Dynamic Slot Numbering Model
To clear the boot.slot.cfg files from the stack’s /flash directories, use the 
 command on all 
modules and then reboot the stack. For example:
-> stack clear slot 1
-> stack clear slot 2
-> stack clear slot 3
-> stack clear slot 4
-> stack clear slot 5
-> stack clear slot 6
-> stack clear slot 7
-> stack clear slot 8
-> reload all
The commands shown above clear the saved slot information from all modules in an eight-module stacked 
configuration and then reboot the stack. Because the system software no longer has preassigned slot infor-
mation to read during the boot process, the stack uses the dynamic slot number assignment method 
described on 
Slot 4 - Idle 
Slot 5 - Idle 
Slot 6 - Idle 
Slot 7 - Idle 
Slot 8 - Idle 
Slot 1 - Primary
Slot 2 - Secondary
Slot 3 - Idle