Klein 59001 drill bit Guida Di Riferimento
242
Wir
e Pulling Grips
Introduction – Wire-Mesh Grips
Table 2
Pulling-Grip Selection Table for Cables of Different
Diameters to Be Pulled in One Grip
Grip Circumference Range
Cat. No. Size
Code
Grip Diameter Range
Fractional
Inches
Decimal
Inches
Fractional
Inches
Decimal
Inches
25/32–1-11/64
.78–1.17
025
1/8–3/8
.12–.37
1-11/64–1-37/64
1.17–1.57
037
3/8–1/2
.37–.50
1-37/64–1-15/16
1.57–1.94
062
1/2–5/8
.50–.62
1-37/64–2-3/8
1.57–2.37
050
5/8–3/4
.62–.75
2-3/8–3-5/32
2.37–3.15
075
3/4–1
.75–1.00
3-5/32–3-15/16
3.15–3.94
100
1–1-1/4
1.00–1.25
3-15/16–4-23/32
3.94–4.72
125
1-1/4–1-1/2
1.25–1.50
4-23/32–5-33/64
4.72–5.51
150
1-1/2–1-3/4
1.50–1.75
5-33/64–6-19/64
5.51–6.29
175
1-3/4–2
1.75–2.00
6-19/64–7-55/64
6.29–7.86
200
2–2-1/2
2.00–2.50
7-55/64–9-7/16
7.86–9.43
250
2-1/2–3
2.50–3.00
9-7/16–11-1/64
9.43–11.01
300
3–3-1/2
3.00–3.50
11-1/64–12-37/64
11.01–12.58
350
3-1/2–4
3.50–4.00
“Grip Circumference Range” refers to circumference of all cables held together.
1. Determine grip circumference range
by measuring circumference
of bundle of cables to be held.
2. Read down to locate correct range.
3. Read across for catalog number
2. Read down to locate correct range.
3. Read across for catalog number
size code.
Example:
For four cables together with circumference of 6.35", use grip
containing catalog number size code “200”.
Table 4
Reference Table: AWG Wire Sizes
For your convenience, the following are representative portable cord diameters.
AWG Wire
Size & Type
Conductors
2
3
4
5
➊
➋
➊
➋
➊
➋
➊
➋
18 SO, STO
3.90
.390
.410
.405
.440
.435
.500
.495
18 SJO, SJTO
.310
.300
.330
.330
.360
.360
–
–
16 SO, STO
.410
.405
.430
.430
.490
.485
.530
.525
16 SJO, SJTO
.330
.330
.340
.360
.390
.390
–
–
14 SO, STO
.530
.530
.560
.560
.610
.605
.680
.685
12 SO, STO
.610
.605
.640
.640
.680
.670
.750
.730
10 SO, STO
.650
.640
.690
.695
.750
.820
.815
–
8 SO, STO
.810
.810
.910
.910
.990
.990
1.080
1.080
6 SO, STO
.930
.930
1.010
1.010
1.100
1.100
1.200
1.200
Table 3
Reference Table: Dimension
Conversions for Ordering Tables
Decimal Inches Fractional
Inches
Metric
Dimensions
(mm)
0.12–0.24
1/8–15/64
3.17–5.95
0.25–0.36
1/4–23/64
6.35–9.13
0.37–0.49
3/8–31/64
9.52–12.30
0.50–0.61
1/2–39/64
12.70–15.48
0.62–0.74
5/8–47/64
15.88–18.65
0.75–0.99
3/4–63/64
19.05–25.00
1.00–1.24
1–1-15/64
25.40–31.35
1.25–1.49
1-1/4–1-31/64
31.75–37.70
1.50–1.99
1-1/2–1-63/64
38.10–50.40
2.00–2.49
2–2-31/64
50.80–63.10
2.50–2.99
2-1/2–2-63/64
63.50–75.80
3.00–3.49
3–3-31/64
76.20–88.50
3.50–3.99
3-1/2–3-63/64
88.90–101.20
Table 5
Reference Table: AWG or MCM
Wire Sizes
This table is to be used as a guide only. Sizes may
vary by manufacturer.
AWG
OR
MCM
Diameter
TTHN
THW
14
.105
.162
12
.122
.179
10
.153
.199
8
.201
.259
6
.257
.323
4
.328
.372
3
.356
.401
2
.388
.433
1
.450
.508
1/0
.491
.549
2/0
.537
.595
3/0
.588
.647
4/0
.646
.705
250
.716
.788
300
.771
.843
350
.822
.895
400
.869
.942
500
.955
1.03
600
–
1.12
700
–
1.19
750
–
1.22
1000
–
1.38