53
12. During the last step of Run Manual Cal, the printer advances the media 
and attempts to detect the label length indicators and stop at the 
Top-of-Form position. The Sensed Distance value will then display for 
one second. The calibrate is successful when the Sensed Distance value 
correctly matches that of the installed media. If “CALIBRATION FAIL/See 
Manual” displays, run a manual calibrate again.
NOTE: The amount of media sampled during manual calibration is based on 
the length of a label and the transitions detected without error, 
between a label and its label length indicators.
13. Press the   (Pause) key until OFFLINE displays.
14. Press the 
 (Feed) key several times. Each time you presss 
 the 
media advances one label length and stops.
NOTE: After a form feed, the position of the leading edge of the next label 
depends on the type of Media Handling mode selected under the 
MEDIA SETUP menu. Tear-Off Strip Media Handling positions the 
label edge at the tear bar, while Continuous positions the label edge 
under the printhead.
15. Once the correct values are confirmed, save them to the desired 
configuration menu before powering off the printer. See “Saving A 
Configuration” on page 147.