Printronix SL4M Manuale Utente

Pagina di 272
DIAGNOSTICS Submenus
143
Feature File
Displays the part number only when a feature file has been installed.
Hex Dump Mode
Disable (factory default).
Enable. The printer prints out data sent from the host in hexadecimal 
format.
Print Error Log
Prints the current log of errors. Most non-routine faults (RIBBON FAULT, 
PRINT HEAD HOT) are stored in the error log.
Clear Error Log
Clears entries in the error log.
FLASH Installed
Displays the amount of FLASH memory installed in megabytes.
EMC FLASH Installed
Displays the amount of EMC FLASH memory installed in megabytes.
DRAM Installed
Displays the amount of DRAM installed in megabytes.
Ptr On Time
Displays the cumulative time in hours the printer has been powered on. This 
value is set to zero at the factory after burn-in testing.
Printer Usage
Displays the cumulative number of inches the printer has moved media. This 
value is set to zero at the factory after burn-in testing.
PrintHead Usage
Displays the length of media actually printed since the last Reset Head Data 
operation. This value is set to zero at the factory after burn-in testing.
Head On Time
Displays the time that power has been applied to the printhead since the last 
Reset Head Data operation. This value is set to zero at the factory after burn-
in testing.