Printronix SL5000r Guida All'Installazione Rapida
Calibrating The Printer
34
To avoid this problem, increase the Threshold Range value to 60%
or 70% in the CALIBRATE CTRL menu (the default is 50%), then
run an Auto Calibrate again (page 30).
or 70% in the CALIBRATE CTRL menu (the default is 50%), then
run an Auto Calibrate again (page 30).
NOTE: Any changes to Threshold Range will not take effect until
you run an Auto Calibrate again.
This will raise the Gap/Mark threshold high enough so that the
printer will not falsely use the antenna as the gap (top-of-form).
printer will not falsely use the antenna as the gap (top-of-form).
255
191
127
063
000
Paper Out(110)
Gap(072)
Detected Amplitude
of the Antenna
Detected Amplitude
of the Gap
Media Sensor
Position
Indicates Type of Gap/Mark
Sensing Selected
FEED