Printronix SL5000r Manuale Utente

Pagina di 396
PRINTER CONTROL Submenus
157
OCR-A Chars.
Character weight adjustment of resident OCR-A characters.
The factory default is 384 and the range is from 0 to 512.
OCR-B Chars.
Character weight adjustment of resident OCR-B characters.
The factory default is 304 and the range is from 0 to 512.
Tall Characters
Increases the point height of resident Intellifont characters.
Enable. Increases the point height of resident Intellifont characters 
approximately 10%.
Disable. Standard resident font character point height is maintained.
The factory default is Disable.
Batch Counter
Displays the number of pages remaining in a print job.
Enable. The # Pages remaining to be printed will display on the second 
line of the control panel LCD. This feature is supported in PGL and 
PPI/ZGL only. The PGL Execute command to support this feature is: 
~EXECUTE;NAME;(#Pages). The PPI/ZGL Execute command is: 
^PQ(#Pages).
NOTE: If the correct execute command is absent from the print file, “0 Pages” 
will continually display on the control panel LCD.
Disable. The # Pages remaining to be printed will not display. Instead, 
the Active emulation and interface will display on the second line of the 
control panel LCD.
The factory default is Disable.
Admin User
Disable. When disabled this function does not permit access to 
submenus which would not normally be changed by a typical user.
Enable. When enabled, this function permits access to submenus which 
would not normally be changed by a typical user.
The factory default is Disable.