Restore The Printer To Operation
Start of image is printed 
an erroneous distance 
from the top-of-form.
The printer starts to print 
one label and then 
another, all within the 
same physical label. 
1.
Make sure the Label Length value matches the actual 
physical length of the label installed and the run on Auto 
Calibrate (see page 72).
These symptoms could be caused by:
severely curled labels near the end of a media roll
the media sensor triggering off of a dark, preprinted image 
on the label
multiple gaps within the physical label.
2.
In the MEDIA CONTROL menu, set Clip Page to Disable.
3.
Run a Media Profile (see page 74).
4.
If the Media Profile printout shows that preprinted images 
or an RFID antenna tag has an amplitude approaching the 
Gap/Mark Threshold level, position the lower media 
sensor to avoid the image or increase the Threshold 
Range percent value in the Calibrate CTRL menu. Run 
Auto Calibrate again and Media Profile to verify there is an 
improvement.
Loss of one or more 
serialized labels within a 
print job.
Start of image is printed 
in the middle of the gap.
The top part of the image 
is lost when printing with 
Head First orientation 
selected.
1.
In the CALIBRATE CTRL menu, set Gap Windowing to 
Enable.
2.
Set Gap Length to equal the physical gap length of the 
media installed. The range is 0.05 to 1.00 inches.
The likely cause of these symptoms is that Clip Page = Enable 
and a cross-perforation, radical fold or flaw in the liner has 
caused the media sensor to detect this as the leading edge 
(TOF) of the new label or end of label (EOF), or both.
Table 16. Printer Problems and Solutions (continued)
Symptom
Solution/Explanation