Printronix P5000 Manuale Utente

Pagina di 186
 100
Chapter
4
IGP/VGL Emulation
NOTE: When Barcode Errors is disabled, the IGP/VGL emulation will try to 
make the best use of invalid data by either truncating extra digits or 
adding zeros to the end of bar code data to meet minimum data 
length requirements for some bar codes. Not all errors will be 
corrected.
Ignore / DB8 Setup
Following are several options which define character filtering and data bit 8.
Ignore Chars
Disable. Character filtering is not enabled. 
Char 1. Character 1 will be filtered. Select the option “Ignore ch#1” to 
specify character 1.
Char 2. Character 2 will be filtered. Select the option “Ignore ch#2” to 
specify character 2.
Char 1&2. Characters 1 & 2 will be filtered. Select the options “Ignore 
ch#1” and “Ignore ch#2” to specify values for these characters.
Ignore ch#1
Specifies character 1 for the character filtering option. Valid decimal values 
are from 0 through 255. 
Ignore ch#2
Specifies character 2 for the character filtering option. Valid decimal values 
are from 0 through 255. 
Data Bit 8
Enable. The PI line is not passed directly from host to printer; all 8 bits are 
used for data bits, and characters in the hex 80-FF range can be 
accessed. 
Disable. When the host PI line is enabled, data bit 8 internally indicates 
PI line status. To use the PI line, disable data bit 8, and enable the Host PI 
configuration option (under the PI Control option, below).
NOTE: Data bit 8 is interpreted as either data bit 8 or PI signal, but never 
both. When enabled as data bit 8, data bit 8 has priority over the PI 
signal, and all data above hex 7F is used to access character data 
and not to interpret PI line data. 
Conversely, when data bit 8 is disabled and the PI signal is used, data bit 8 of 
the data is reserved for use as the PI function, and you cannot access 
characters in the hex 80-FF range. Therefore, to access characters in the hex 
80-FF range, data bit 8 must be enabled.