Printronix P5000 Manuale Utente

Pagina di 186
Parallel Submenu
 107
Parallel Submenu
Centronics Interface
IMPORTANT
The Centronics parameters in the printer must be set the same as the 
Centronics interface in the host computer. Otherwise, the printer might 
not work online, and data characters from the computer might not print 
or might print as “garbled” text.
The Centronics submenu provides the options and settings available to 
configure the interface as required for your application. These options and 
available settings are outlined in the following paragraphs.
Data Bit 8
Enable. Allows access to the extended ASCII character set. 
Disable. The printer interprets bit 8 of each incoming data character as a 
zero, regardless of its actual setting.
Data Polarity
The Data Polarity parameter must be set to match the data polarity of your 
host computer. 
Standard. Does not expect the host computer to invert the data.
Inverted. Expects the data received on the data lines from the host 
computer to be inverted. Ones become zeros, and vice-versa.
Parallel
Data Bit 8
Data Polarity
Strobe Polarity
Resp. Polarity
Busy On 
Strobe
Latch Data On
Prime Signal
TOF Action
Enable*
Disable
Standard*
Inverted
Standard*
Inverted
Standard*
Inverted
Enable*
Disable
Leading*
Trailing
Enable*
Disable
Reset*
Do Nothing
* = Factory Default
Centronics
Buffer Size in 
K
8*
(1-16)