RS-232 and RS-422 Serial Interface Signals
 131
RS-232 and RS-422 Serial Interface Signals
The RS-232 connector mounted on the printer is a 25-pin DB-25S type. The 
mating connector is a DB-25P. RS-232 and RS-422 compatible serial 
interface signals are defined as follows:
RS-232
Received Data (RD). Serial data stream to the printer.
Transmitted Data (TD). Serial data stream from the printer for transmitting 
status and control information to the host. Subject to protocol selection.
Request To Send (RTS). Control signal from the printer. Subject to 
configuration.
Clear To Send (CTS). Status signal to the printer indicating the host is ready 
to receive data/status signals from the printer.
Data Set Ready (DSR). Status signal to the printer indicating the host is in a 
ready condition.
Data Carrier Detect (DCD). Status signal to the printer. The ON condition is 
required for the printer to receive data.
Data Terminal Ready (DTR). Control signal from the printer. Subject to 
configuration.
RS-422
+RD, -RD. Serial data stream differentially received by printer.
+TD, -TD. Differentially driven serial data stream for transmitting status and 
control information to the host. Subject to protocol selection.
NOTE: ±RD and ±TD form signal and return paths of a differential line 
signal.
RS-232 and RS-422 Serial Interface Protocol
XON/XOFF. The printer transmits an XON character (hex 11) when entering 
the online mode or when the buffer is almost empty. The printer transmits an 
XOFF character (hex 13) when entering the offline mode or when the buffer is 
almost full.
RS-232 and RS-422 Serial Interface Error Handling
NOTE: All serial errors are treated as faults that require operator intervention.
Parity Error Handling. Parity error checking is a configuration option 
selected from the control panel.
With odd or even parity checking selected, a character with a parity error is 
replaced with a question mark (?) character.
When parity checking is not selected (“NONE” on the control panel), parity 
errors are ignored and the characters are printed as received.