Printronix P5000 Manuale Utente

Pagina di 186
P-Series Emulation
 87
Control Code 06
Control Code 06 defines the function of ASCII code hex 06 (ACK). You can 
select an alternate line spacing of 6, 8 or 10.3 LPI.
Control Code 08
Control Code 08 defines the function of ASCII code hex 08 (BS). You can 
define the code to output an elongated character or a backspace.
Define CR Code
This option controls the action of the printer when it receives a Carriage 
Return code (hex 0D) from the host computer. If this feature is enabled, each 
time the printer receives a Carriage Return, it inserts an additional Line Feed 
code (hex 0A) into the data stream. Do not use this feature if the host 
computer sends Line Feeds to the printer. 
CR = CR. Does not insert an extra Line Feed after each Carriage Return.
CR = CR + LF. Inserts an extra Line Feed after each Carriage Return. 
The next print position will be print position 1 of the next line.
Auto LF
This option defines the printer action when print data is received past the 
forms width setting. 
Disable. Discards any data past the forms width.
Enable. Performs an automatic carriage return and line feed when data is 
received past the forms width.
Overstrike
Enable. Common dots appear darker in characters printed over each 
other, as shown below. The print position moves one-half dot to the right. 
Overstrike printing occurs at a decreased speed.
Disable. If you are using a control code for overstrike, but it is disabled in 
the printer control panel, no bolding will occur. 
Define LF Code
LF = CR + LF. Forces an automatic carriage return with each line feed 
command. The next print position is print position 1 of the next line.
LF = LF. Does not perform an automatic carriage return. The next print 
position will be the current print position of the next line.