Configuring the PCL-II Emulation with Control Codes
Printing Bar Codes
Generally, sending bar code information to the printer is performed in two 
steps:
Step 1: Selecting the bar code printing specifications; bar code type, height, 
and header control information.
Step 2: Moving the cursor to the desired label location and sending the bar 
code data.
Step 1 
Before positioning and printing the bar code data, the type of code, height of 
the label, and header placement may be specified. Once this is done, the 
succeeding labels will be printed using these specifications until a new type, 
height, or header control is specified. In other words, the bar code print 
specifications can be sent once and need not be sent again unless the printer 
is reset or new print specifications are desired. The following example 
specifies the print specifications for bar codes that are 0.5 inches in height, 
have a header above the label, and are printed in the UPC A code.
ESC*z8v5h1Q
ESC*z8v
Select UPC A code
5h
Label is to be .5 inches high
1Q
Places header above bar code
Notice that the last letter in the escape sequence (Q) is upper-case while the 
other letters in the sequence (v and h) are lower-case. (See “Escape 
Sequences” on page 25 fo
r more information concerning combining two or 
more sequences.)
Step 2 
To print a bar code label, the cursor must be placed in the desired position 
and the bar code data must be sent. The following escape sequence moves 
the cursor to column 25, sends the data “1234567” to the printer, and initiates 
printing.
ESC*z25c<1234567>Z
ESC*z25c Places start of label at column 25
<
Indicates start of bar code data
1234567
Bar code data
>
Signals end of bar code data
Z
Upper case Z initiates printing *
*Note that an upper-case “Z” terminator results in the bar code being printed 
and an automatic carriage return (CR) being executed.