Using The Advanced RFID Calibration
Tag Profiler
The Tag Profiler maps the tag position with optimized read and 
write power settings.
Before running the Tag Profiler, it is important that the proper Gap 
Sensing procedure has been followed. (Refer to “Calibrating The 
Printer” in the 
User’s Manual.)
To use the Tag Profiler, first ensure that the tag type that you have 
selected from the Tag Type menu (see “Tag Type” on page 22 
[SL5000r] or page 39 [SL4M] for a list of supported tag types) either 
matches the tag type you are about to calibrate or is at least of the 
same Class and data length (i.e. 64 or 96 bits). Next, check that 
Custom Tag is set to Duplicate. The correct defaults will then be set 
for Custom Tag Class and Tag (EPC Byte) Length.
Prior to initiating the calibration cycle, the Tag Profiler can be 
optimized by setting appropriate limits on the following four custom 
entries:
Custom (Scan) Start Pos. Identifies the starting position of the 
calibration scan. The default will start at the Top Of Form 
(TOF). To avoid inefficient scanning at points far away from the 
target tag, set the (Scan) Start Pos within one inch of the center 
of the physical tag. E.g., if the center of the tag is physically 
three inches from the TOF, set (Scan) Start Pos to 2 inches 
(one inch before the center of the tag).
Custom Scan Length. The distance the Tag Profiler will scan 
to determine the optimum tag position. For improved 
performance, set Custom Scan Length to 2 inches or less. This 
will prevent the printer from looking for a tag far beyond its 
actual location.
Custom (Cal) Min Power. Sets the lower level that will be 
tested during calibration. To speed up calibration, set Custom 
Min Power to two points lower than the Custom Read Power 
that was set prior to initiating calibration.