RFID ZGL Commands
74
8–byte or 12–byte blocks, the number of 
blocks to be read can only be 1.
e
Specifies the memory bank to write to or 
read from. The default is E.
E = EPC
0 = Reserved
1 = EPC
2 = TID (only for read)
3 = USER
Calibrate RFID Transponder Position
Purpose
This command initiates an RFID RFID transponder 
calibration for a specific RFID label and returns the 
results to the host computer.
Format
^HR
a,b
^HR
Calibrate RFID command.
a
The start string to appear before the 
returned result. The default is “start”. The 
acceptable value is any string less than 65 
characters.
b
The end string to appear after the returned 
result. The default is “end”. The acceptable 
value is any string less than 65 characters.
Define EPC Data Structure
Purpose
This command defines the structure of EPC data, 
which can be read from or written to an RFID 
transponder.
Format
^RB
p0,p1,p2...,p15
^RB
EPC Data command.
n
Total bit size of the field. The default is 96. 
The acceptable value range is 1 to 
n, 
where 
n is the total bit size of the tag.
p1...p15
Specifies each partition size. These must 
add up to the total bit size. The default is 1. 
The acceptable value range is 1 to 64 bits 