Return Status Port
The PGL VERIFY command (page 64) and ZGL ^HV command 
(page 79) require the use of the Return Status port. Set this port 
using Ret. Status Port in the PGL SETUP or ZGL SETUP menu.
NOTE: If you are using the PGL SETUP menu, you must set 
Admin User to Enable in the PRINTER CONTROL menu.
If you set Ret. Status Port to Serial, you must set all SERIAL PORT 
menu settings (i.e., Port Type, Baud Rate, Stop Bits, Parity, etc.) to 
match the serial port settings in the application.
If you set Ret. Status Port to E-NET Data Port or E-NET Stat Port, 
you must set the application to connect using TCP/IP. The Host 
Address must match the IP Address SEG 1 through IP Address 
SEG 4 settings in the ETHERNET ADDRESS menu. Set the Port 
Number to 9001 for E-NET Data Port, or 3002 for E-NET Stat Port.