Printronix SL5000 Manuale Di Riferimento

Pagina di 338
 252
Chapter
7
Bar Codes
MSI
The MSI bar code structure is shown in Figure 17 and described below.
Figure 17. MSI Structure
Quiet Zone
Both ends of the bar code structure require blank quiet zones. The quiet 
zones must be at least 0.25-inches wide and completely blank to ensure 
accurate reading of the start/stop codes and to prevent adjacent bar codes 
from overlapping. You must provide sufficient space on the form for the quiet 
zones.
Start/Stop Code
Unique start and stop codes permit bidirectional scanning. Both start and stop 
codes contain bars and spaces. They are automatically produced.
Data Field
The bar code symbol uses a series of wide and narrow bars and spaces to 
represent each numeric character. The structure is four wide elements (bars 
or spaces) and four narrow elements. Each character contains four data bits, 
with each 0-bit made up of a narrow bar/wide space arrangement and each 1-
bit made up of a wide bar/narrow space arrangement.
Readable Data
The optional readable data field provides a readable interpretation of the bar 
code data. It can be printed above or below the bar code symbol.
Check Digit
If specified, the modulo-10 or modulo-11 (or both) check digit is automatically 
calculated and inserted in the bar code symbol. The check digit verifies 
accurate scanning.
DATA FIELD
QUIET
QUIET
START
STOP
LOWER GUARD BAND
CODE
CODE
ZONE
ZONE
OPTIONAL READABLE DATA FIELD
CHECK DIGIT
OPTIONAL
SR, SC
HEIGHT
POSITION
UPPER GUARD BAND