Hafler P1500 Guida Specifiche

Pagina di 2
S
PECIFICATIONS
P1500
Power Rating ....................................................................... 75 Watts/channel @ 8
Ω
85 Watts/channel @ 4
Ω
170 Watts bridged/mono @ 8
Ω
Total Harmonic Distortion (THD) ................................................ <0.2% (20Hz-20kHz)
Signal-to-Noise .......................................................................... 100dB “A” Weighted
Full Power Bandwidth .................................................... 0.15Hz to 300kHz (+0/–3dB)
Slew Rate ....................................................................................................... 100V/
µ
s
CMRR (Common Mode Rejection Ratio) .............................................. 75dB at 1kHz
Input Impedance ........................................................... 47k
Ω
 per phase balanced
Gain ................................................................................... +14dB min. / +29dB max.
Input Sensitivity Range ...................... 437mV to 2.4V (@ 8
Ω
) per phase balanced
330mV to 1.8V (@ 4
Ω
) per phase balanced
Damping Factor ..................................................................................... 350 (to 1kHz)
150 (to 10kHz)
18 (to 100kHz)
Power Consumption ......................................... 60W / 500mA @ 120VAC (idle power)
230W / 1.9A @ 120VAC (1/8 power – 8
Ω
)
325W / 2.70A @ 120VAC (max. power – 8
Ω
)
Indicators .................................................. Power, Signal, Clipping, Thermal, Short
Dimensions ...................................................... 19”W x 8
1
2
”D x 3
1
2
”H (2-rack spaces)
(48.26cm x 12.59cm x 8.89cm)
Net Weight ....................................................................................... 21.6 lbs. (9.98kg)
A
m
p
l
i
f
i
e
r
P1500
®
A
RCHITECT
S
 
AND
 E
NGINEER
S
 S
PECIFICATIONS
The audio power amplifier shall be solid state design employing 4 lateral
power MOSFET output devices. It shall be constructed on a 16 gauge steel
chassis utilizing convection cooling and be technician friendly using modular
construction.
Each channel shall be rated for a minimum of 75 watts into an 8 ohm load and
85 watts into a 4 ohm load with both channels driven. In bridged mono mode,
the amplifier shall produce at least 170 watts into an 8 ohm load. A switch shall
be provided for stereo or bridged mono operation and all power ratings shall
be measured from 20Hz-20kHz with less than 0.2% THD.
The amplifier’s back panel shall provide Balanced inputs via combination XLR
and 1/4” phone jacks. The back shall also utilize gold-plated 5-way binding
posts for output connectors and a switch to isolate or connect the signal
ground to the chassis ground. The amplifier shall include a 3-wire grounded
AC line cord and UI power transformer operating on 120V/60Hz AC mains. An
optional transformer for 230V 50-60Hz operation shall be available.
The amplifier’s front panel shall provide level controls with optional security
covers. The front shall also incorporate a lighted main power switch and
indicators for each amplifier channel. The indicators shall display signal
present when 30mV of signal is detected, signal clipping when distortion rises
above 1%, thermal protection should the heatsink temperature become exces-
sive, and short circuit protection in case a problem on the speaker system
arises.
The amplifier shall fit standard 19” EIA rack mounting requirements utilizing 2-
rack spaces. The dimensions shall be 19” Wide, 8
1
2
” Deep, 3
1
2
” High, and be
finished in black with a net weight of 21.6 pounds. It shall be a Hafler P1500.
• Use CH 1 Input ONLY
• Set CH 2 Gain to Max
• Set Output Level with
   CH 1 Gain Control
A Division of Rockford Corp.
Tempe, AZ 85281  U.S.A.
Made in the U.S.A.
XLR Connections
3
2
1
+
Phone Connections
+
®
115V ~
60Hz
CH 1 (Mono)
C H   1
 
+
4-8
Ω
C H   2
 
+
 
+
Mono
P1500
250 V T4A
CAUTION: For continued
protection from risk of
fire, replace only with
same type and
rating of fuse.
CH 2
Audio Ground
Chass. Float
Mono
2-Ch
Mono Output:
8
Ω
4-8
Ω
WARNING:  DO NOT REMOVE COVER
TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK
DO NOT EXPOSE THIS EQUIPMENT TO RAIN OR MOISTURE.
!
C A U T I O N
RISK OF ELECTRIC SHOCK
DO NOT OPEN
PUSH
PUSH
UL
®
UL
®
C