Roland HP203 Guida Utente

Pagina di 108
 
73
 
Various Settings
 
Here you can make various MIDI-related settings for the 
HP203.
For more about MIDI, refer to “Connecting to MIDI Devices” 
(p. 82).
When you have a MIDI sequencer connected, set this 
parameter to Local Off. 
Since the Thru function of your sequencer will normally be 
turned on, notes played on the keyboard or played back by 
the recorder will be transmitted to the sound generator by the 
two routes (1) and (2) shown in the illustration, causing notes 
to be sounded in duplicate or to be cut off unnaturally. To 
prevent this, the setting called “Local Off” is used to disconnect 
the route in (1).
 
fig.LocalCntr.j
 
Local On:
 
The keyboard and recorder are connected to 
the internal sound generator.
 
fig.LocalOn.j
 
Local Off:
 
The keyboard and recorder are not connected 
to the internal sound generator. No sound will be produced by 
the keyboard when it is played.
 
fig.LocalOff.j
 
1.
 
Hold down the [Brilliance] button and press 
the [3D] button.
 
The display will indicate “Fnc” and you’ll be in Function 
mode.
 
2.
 
Hold down the Track [Accomp] button and use 
the [-] [+] buttons to make the display indicate 
“L.Ct.”
 
When you take your finger off the button, the display 
will indicate the value of the setting.
 
3.
 
Use the [-] [+] buttons to change the setting.
 
When connecting a unit in the Roland MT series, you 
don’t need to switch off Local Control. MT units 
transmit Local Off messages when their power is 
switched on. If you first switch on the HP203, then 
the MT-series device, Local Control is automatically 
switched off on the HP203.
 
MIDI Settings
 
Preventing Doubled Notes When 
Connected to a Sequencer (Local Control)
(1)
MIDI
MIDI
MIDI
MIDI
(2)
IN
IN
OUT
OUT
Sequencer
Memory
Sound
Generator
Each note played is sounded twice
Soft Thru On
Local On
Local On
Sound is emitted
Sound Generator
Local Off
No sound produced
Sound Generator
 
Setting
Explanation
 
The Local Control is set to On.
The keyboard and recorder are connected to the 
internal sound generator.
The Local Control is set to Off.
The keyboard and recorder are not connected to the 
internal sound generator. Playing the keyboard or 
playing back a song will not produce sound.
NOTE
HP203_e.book 73 ページ 2007年7月17日 火曜日 午前10時46分