Enterasys csx200 Guida Utente

Pagina di 261
CSX200 Family User’s Guide 25
4
Installation
This chapter outlines the procedure for attaching the CSX200 to the network. Ensure that the 
network meets the guidelines and requirements outlined in 
, before installing the CSX200.
Unpacking the CSX200
Unpack the CSX200 as follows:
1.
Remove the shipping material from the box and carefully remove the CSX200.
2.
Visually inspect the CSX200. If there are any signs of damage, contact Cabletron Systems (see 
the 
3.
Read the CSX200 Release Notes included in the shipping box.
Guidelines for Installations
3
Installation sites must be within reach of the network cabling and meet the requirements listed 
below:
A properly grounded power receptacle must be within seven feet of the location.
In a shelf installation, the shelf must be able to support 13.6 kg (30 lb) of static weight for each 
device on the shelf. 
Maintain a temperature of between 5
°
C (41
°
F) and 40
°
C (104
°
F) at the installation site with 
fluctuations of less than 10
°
C (50
°
F) per hour.
Maintain a two-inch clearance for each side and the back of the device for adequate ventilation.
Only qualified personnel should perform installation procedures.