Enterasys csx150 Guida All'Installazione Rapida

Pagina di 49
QUICK START
34      CyberSWITCH
4.
Under Security, select Device Level Databases, select On-node Device Entries, then add a device 
where the Device Name (Central) must match the system name on Central. When you add the 
device you must then enter the following information:
a.
Under ISDN Information make sure the ISDN Line Protocol is PPP.
b.
Under ISDN Information you must enter a dial out number (13135551111) and a base data 
rate (64Kb).
c.
Under Authentication you must:
Change CHAP Secret so that it matches Central’s System secret (Central_S). 
Optional: Configure Calling Line Ids (if Calling Line Id security was enabled).
d. Under Bridging you must:
Make sure that Bridging is enabled
Make sure that Make calls for Bridge Data is enabled.
5.
Under Options, select Bridging, then select Bridge Dial Out. Make sure dial out is enabled. Then 
add the device (Central) that you wish to call when you receive a ethernet packet that is not on 
the same LAN as Remote. Note that the bridge dial out configuration is slightly different for 
Remote than it was for Central.
IP R
OUTER
 
TO
 IP R
OUTER
 C
ONFIGURATION
C
ONFIGURATION
 
FOR
 S
ITE
 "C
ENTRAL
"
The configuration on Central to allow IP Routing to Remote using PPP is as follows:
1.
Perform 
 steps.
2.
Under Options, select Bridging, then disable Bridging. Select IP Routing, then:
a.
Enable IP Routing.
b.
Under IP Interfaces add a LAN Interface (IP address 199.2.2.1).
c.
Under IP Interfaces add a WAN UnNumbered Interface.
3.
Under Security, select System Options and Information, then under System Information:
a.
Set your System Name (Central). This matches up with Central device information 
configured on Remote.
b.
Set your System Secret (Central_S). This matches up with Central device information 
configured on Remote.
Site IP Address 199.2.2.0
"Central"
LAN IP Address 199.2.2.1
Phone 13135551111
"Remote"
LAN IP Address 201.1.2.1
Phone 13135552222
ISDN
Site IP Address 201.1.2.0
POWER
SERVICE
TX
RX
10BASE - T
LAN                                                                                      B-CHANNELS                                                                          E1 ONLY 
B2 B4
B6 B8
B26 B28
B22 B24
B18 B20
B14 B16
B10 B12
B30 L1
B1 B3
B5 B7
B25 B27
B21 B23
B17 B19
B13 B15
B9 B11
B29 B31
E1
D
T1
D
CSX1200
CSX150