Enterasys csx150 Guida Utente

Pagina di 620
USER’S GUIDE
358      CyberSWITCH
V
ERIFYING
 
THE
 D
IAL
 O
UT
 F
EATURE
To perform the Dial Out verification for a remote device, you need to know the configured device 
name associated with the device’s device table entry. Note that the device name is case sensitive. If 
you already know the device name, skip to step 4. Otherwise, begin the verification process with 
step 1.
1.
Enter the Manage Mode by typing the following command at the system prompt:
>
manage
2.
Enter the following command at the Manage Mode prompt to display the current on-node 
device table:
MANAGE> 
device
 
Make note of the device name for verification of the Dial Out feature.
3.
Exit the Manage Mode by entering the following command:
MANAGE> 
exit
4.
The following administrative command is used to verify that the Dial Out feature is operational 
to a specific remote device:
call device <device name>
For example, to verify that the Dial Out feature is operational for remote device with fred as the 
configured device name, you would enter 
call device fred 
at the system prompt.
5.
A message will be displayed indicating whether or not the call was made successfully. Refer to 
in the Problem Diagnosis chapter if the call was not made successfully.
V
ERIFYING
 C
ALL
 D
ETAIL
 R
ECORDING
The 
cdr verify 
console command is used to verify that the Call Detail Recording (CDR) feature 
is operational. This command will send a sample message to all servers that have been configured 
for CDR. Check the log file of each server to verify that the message was logged. The message will 
be similar to the example below; additional data items may be added in future releases.
 
<System Name>    CDR VERIFY 1 of 1
In order for the 
cdr verify
 console command to be useful, an Ethernet LAN must be operational 
and an IP route to all off-node servers must be defined and operational. The command can be 
performed before all the WAN equipment is in place and configured.
Additional verification can be performed by forcing the logged events to occur and checking that 
they are indeed logged. This would require that all WAN equipment and configuration is in 
operational order. 
The Connect and Disconnect events require a successful connection; a Reject event can be forced by 
supplying a bad PAP password, for example.
If the 
cdr verify 
console command fails for an off-node server, refer to
 in 
the Problem Diagnosis chapter.