Enterasys csx150 Guida Utente

Pagina di 620
Small Office Remote Access Switch      401
LED I
NDICATORS
Service Indicator
S
ERVICE
 I
NDICATOR
 R
EMAINS
 L
IT
If the Service indicator remains lit during the power-on sequence, this means the system software 
is unable to boot. The system may be having some type of operational problem. While the Service 
indicator remains lit, the other LEDs will blink a certain number of times, pause, then blink that 
number of times again (See following table). This pattern will be repeated five times. The actions to 
take if this occurs are:
1.
Make note of the number of consecutive blinks. 
2.
Restart the system.
3.
If the Service LED is still lit, and the other LEDs are still flashing, contact your distributor and 
provide them with the count of consecutive blinks.
The table below provides an error description corresponding to the number of consecutive LED 
blinks: 
* FSB: First Stage Boot;   SSB: Second Stage Boot. 
S
ERVICE
 I
NDICATOR
 B
LINKS
If the Service indicator blinks at any time during system operation, access your administrative 
console (using the status command) for further information. One or more of the following messages 
should be displayed: 
OUT  SVC  1
OUT  SVC  2
OUT  SVC  3
OUT  SVC  4
OUT  SVC  5
LAN XMIT ERROR
Number of Blinks
Error Description
1
Failure during erasure of main block during SSB* recovery
2
Failure during programming of main block during SSB 
recovery
3
Timed out during recovery of SSB
4
Individual record error during recovery of SSB
5
Communications error during recovery of SSB
6
Incompatibility between FSB* and new SSB versions
7
Currently not used
8
Bad address information contained in SSB received during 
recovery
9
SSB, received during Recovery, contained a bad checksum 
for entire image