Axis 211W Guida Utente

Pagina di 52
AXIS 211W - Using the Network Camera 
 
Accessing the AXIS 211W from the Internet
Once configured, your AXIS 211W is accessible on your local network (LAN). To access the camera from the 
Internet, network routers must be configured to allow incoming traffic, which is usually done on a specific port. 
To do this, enable the NAT-traversal feature, which will attempt to automatically configure the router to allow 
access to the camera. This is enabled from Setup > System Options > Network > TCP/IP Advanced. 
Dynamic DNS Service at www.axiscam.net or, for Technical notes on this and other topics, visit the Axis 
Support Web at www.axis.com/techsup
The Live View Page
Not all the buttons described below will be visible unless the Live View page has been customized to display 
them.
w
The Video Format drop-down list allows the video format on the Live View page to be 
temporarily changed. 
These buttons start and stop the Sequence Mode. This mode is created in Setup > Live View 
Config > Sequence mode, and automatically displays the view from 2 or more video sources at set 
intervals.
From the Source list, select the desired external video source. Note that Sequence Mode 
must be stopped before selecting a source from this list.
 
The Trigger buttons can trigger an event directly from the Live View page. These are configured 
under Setup > Live View Config > Layout.
The Snapshot button saves a snapshot of the image currently displayed. Right-click on the video 
image to save it in JPEG format on your computer. This button is intended for use when the AMC 
viewer toolbar is not available.
The AMC (AXIS Media Control) viewer toolbar is available in Microsoft Internet Explorer for Windows only. 
It displays the following buttons:
Play/Stop button - starts and stops the live video stream.
Snapshot button - saves a snapshot of the video image currently displayed. The Snapshot function and 
the target directory for saving snapshots can be configured from the AMC Control Applet in the 
Windows Control Panel (Internet Explorer only).
The Output buttons control the output directly from the Live View page. These buttons are configured under 
Setup > Live View Config > Layout.
Pulse - click this button to activate the output for a defined period of time, e.g. to switch on a light 
for 20 seconds.
Active/Inactive - click these buttons to manually start and stop a connected device, e.g. switch a 
light on/off.