Door Alignment Check and Adjustment
IMPORTANT
IMPORTANT
Properly aligned, the door’s gasket should be firmly 
in contact with the cabinet all the way around the 
door (no gaps). Carefully examine the door’s gasket 
to assure that it is firmly in contact with the 
cabinet. Also make sure the door gasket is not 
pinched on the hinge side of the door.
Figure 12
1. Loosen (do not remove) top (Figure 12) and bottom 
hinge screws.
2. Align door squarely with cabinet.
3. Make sure gasket is firmly in contact with cabinet all 
the way around the door (no gaps). 
4. Tighten bottom hinge screws.
5. Tighten top hinge screws.
Door Reversal
Black or white unit doors may be left- or right-hand 
opening. Depending upon the location of the unit, it may 
be desirable to change the side on which the door is 
mounted.
6.
Black or White Model
To reverse the door, perform the following:
1. Remove the grille (two screws).
Figure 13
2. Remove top hinge from cabinet (four screws) (Figure 
13). Hold door to keep it from falling.
3. Lift the door off the bottom hinge.
Figure 14
4. Remove four plastic plugs (Figure 14) in hinge holes, 
top of cabinet, opposite side. Be careful not to scratch 