ATTO Technology diamond array v Manuale Utente

Pagina di 117
21
 
ATTO Technology Inc. Diamond Storage Array Installation and Operation Manual
 4.2  Serial Port Access
The Diamond Storage Array provides remote service operations over the RS-232 serial port using 
standard terminal emulation software available with most systems. 
The Diamond Storage Array supports service 
operations over the RS-232 serial port using 
standard terminal emulation software available 
with most systems.
1
Connect a DB-9 null modem serial cable 
between the port marked RS-232 on the front of 
the array and one of the computer’s serial ports. 
A gender changer or DB-9 to DB-25 converter 
may be needed depending on the cables you 
are using. The cable must be no longer than 
three meters.
2
Boot the computer used to manage the array.
3
Start a terminal emulator program such as 
Windows HyperTerminal. Set the emulator to 
use the COM port with cable attached, then the 
following settings: 
• 115200 
baud 
•  8 bit ASCII 
• no 
parity 
•  ASCII terminal type 
•  1 stop bit 
• flow 
control 
none 
•  echo typed characters locally
4
Turn on the array. Upon successful power on 
and diagnostics, the unit should display the 
POST (power on self test) information found in 
Exhibit 4.0-1on page 18. 
5
You should now be in the Command Line 
Interface mode. To see a list of available 
commands, type help at the Ready prompt or 
refer to this manual’s Index.
6
Use the CLI to configure the unit as a JBOD, 
RAID Level 0, RAID Level 1, RAID Level 10 or 
RAID Level 5 array with partitions, zones and/or 
hot spare sleds as described later in this 
manual.