ATTO Technology diamond array v Manuale Utente

Pagina di 117
24
Ethernet protocols
6
Type SaveConfiguration restart to reboot the 
array.
7
Install SNMP management software on each 
client you wish to receive traps (messages).
8
Call technical support to get the appropriate 
MIB file for your array.
9
For each client, copy the MIB file to the 
directory containing the SNMP management 
software.
10 From within the SNMP management software, 
compile the file attodmnd-mib.mib according to 
the software’s procedures.
11 Unload any default MIBs.
12 Load the Diamond MIB ATTODIAMOND.
13 When requested, enter the array’s IP address 
as the Remote SNMP Agent.
14 The SNMP management software contacts the 
agent in the array. The screen replies with 
system information. 
15 Status is monitored and reported through the 
SNMP management software. 
Traps are generated for the following situations:
•  Temperature status changes in any of the 
sensors located on the array mid-plane.
•  A drive or a sled is physically removed from the 
Array or put into the Array.
•  The power supply is turned on or off.
•  The fan is physically stopped.