A. Configuration Options
A-32
 
 September 2004
7990-A2-GB20-20
Enterprise Specific Traps
Possible Settings: Enable, Disable
Default Setting: Disable
Determines if SNMP traps are generated for enterprise-specific events.
Enable – SNMP traps are generated for enterpriseSpecific events.
Disable – No enterprise-specific event traps are sent.
NOTE: Refer to 
Link Traps
Possible Settings: Disable, Up, Down, Both
Default Setting: Both
Determines if SNMP traps are generated for link up and link down for one of the 
communication interfaces. 
Disable – No linkUp or linkDown SNMP traps are generated.
Up – A linkUp trap is generated when the unit recognizes that one of the communication 
interfaces is operational.
Down – A linkDown trap is generated when the unit recognizes a failure in one of the 
communication interfaces.
Both – Sends trap messages for detection of both linkUp and linkDown.
NOTE: Refer to 
Link Traps Interfaces
Possible Settings: 
  7995: Network, SYNC, All
  7996: Network, G.703, All
Default Setting: All
Determines if the SNMP linkUp, SNMP linkDown, and interface-related enterpriseSpecific 
traps are generated for the network interface, synchronous or G.703 interface, or both. 
Network – SNMP trap messages are generated for the network interface.
SYNC – SNMP trap messages are generated for the synchronous interface.
G.703 – SNMP trap messages are generated for the G.703 interface.
All – SNMP trap messages are generated for the network interface and the synchronous 
or G.703 interface.
Table A-12. SNMP Traps Options (2 of 2)