4. Configuring the Unit Using the Internal Switches
4-2
May 2002
7990-A2-GB20-00
Configuring the Unit Using Internal Switches
Use internal Switchpacks S3 and S4 to manually configure the unit.
HANDLING PRECAUTIONS FOR
STATIC-SENSITIVE DEVICES
STATIC-SENSITIVE DEVICES
This product is designed to protect sensitive components from damage
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
due to electrostatic discharge (ESD) during normal operation. When
performing installation procedures, however, take proper static control
precautions to prevent damage to equipment. If you are not sure of the
proper static control precautions, contact your nearest sales or service
representative.
Procedure
To configure the unit using internal Switchpacks S3 and S4:
1. Power off the unit.
2. Remove the enclosure cover:
— Use a Phillips screwdriver to remove the two screws from the top of
the unit.
— Push a flat-blade screwdriver through the slots on both sides of the
housing to free the four inner latches.
3. Locate Switchpack S3 on the circuit board using
.
4. Set Switch 1 on Switchpack S3 to ON to enable Switchpacks S3 and S4.
5. Set the switches to the desired configuration.
— For Model 7995, refer to
and
.
— For Model 7996, refer to
and
.
6. Replace the cover and fasten it with the two screws.
7. Power on the board to reset the unit and enable the new configuration.
!