HP 4208vl J8773A Dépliant

Codici prodotto
J8773A
Pagina di 22
Performance
Performance
Performance
Performance
Latency
Latency
Latency
Latency
< 6 µs (FIFO)
Throughput
Throughput
Throughput
Throughput
Up to 22.4 million pps
Switch fabric speed
Switch fabric speed
Switch fabric speed
Switch fabric speed
33.6 Gbps
Environment
Environment
Environment
Environment
Operating temperature
Operating temperature
Operating temperature
Operating temperature
32°F to 104°F (0°C to 40°C)
Operating relative
Operating relative
Operating relative
Operating relative
humidity
humidity
humidity
humidity
15% to 95% @ 104°F (40°C), non-condensing
Non-operating/
Non-operating/
Non-operating/
Non-operating/
Storage temperature
Storage temperature
Storage temperature
Storage temperature
–40°F to 158°F (–40°C to 70°C)
Non-operating/
Non-operating/
Non-operating/
Non-operating/
Storage relative humidity
Storage relative humidity
Storage relative humidity
Storage relative humidity
15% to 95%, non-condensing
Altitude
Altitude
Altitude
Altitude
up to 15000 ft. (4.6 km)
Acoustic
Acoustic
Acoustic
Acoustic
Power: 64.2 dB; DIN 45635T.19 per ISO 7779
Electrical characteristics
Electrical characteristics
Electrical characteristics
Electrical characteristics
Maximum heat dissipation
Maximum heat dissipation
Maximum heat dissipation
Maximum heat dissipation 2152 BTU/hr (2270 kJ/hr)
Voltage
Voltage
Voltage
Voltage
100-127 / 200-240 VAC
Current
Current
Current
Current
8.2 / 3.8 A
Power consumption
Power consumption
Power consumption
Power consumption
630 W
Frequency
Frequency
Frequency
Frequency
50/60 Hz
Notes
Notes
Notes
Notes
Maximum power rating and maximum heat dissipation are the worst-case
theoretical maximum numbers provided for planning the infrastructure with
fully loaded PoE (if equipped), 100% traffic, all ports plugged in, and all
modules populated.
Safety
Safety
Safety
Safety
CSA 22.2 No. 950; UL 60950; EN 60950
Emissions
Emissions
Emissions
Emissions
FCC Class A; VCCI Class A; EN 55022/CISPR 22 Class A;
CISPR 22 Class A; EN 55024; IEC/EN 61000-3-2; IEC/EN 61000-3-3
Immunity
Immunity
Immunity
Immunity
EN
EN
EN
EN
EN55024, CISPR 24
ESD
ESD
ESD
ESD
IEC 61000-4-2
Radiated
Radiated
Radiated
Radiated
IEC 61000-4-3
EFT/Burst
EFT/Burst
EFT/Burst
EFT/Burst
IEC 61000-4-4
Surge
Surge
Surge
Surge
IEC 61000-4-5
Conducted
Conducted
Conducted
Conducted
IEC 61000-4-6
Power frequency
Power frequency
Power frequency
Power frequency
magnetic field
magnetic field
magnetic field
magnetic field
IEC 61000-4-8
Voltage dips and
Voltage dips and
Voltage dips and
Voltage dips and
interruptions
interruptions
interruptions
interruptions
IEC 61000-4-11
Harmonics
Harmonics
Harmonics
Harmonics
EN61000-3-2, IEC61000-3-2
Flicker
Flicker
Flicker
Flicker
EN61000-3-3, IEC61000-3-3
Management
Management
Management
Management
HP ProCurve Manager Plus; HP ProCurve Manager (included); command-
line interface; Web browser; configuration menu; out-of-band management
(DB-9 serial port console); IEEE 802.3 Ethernet MIB; Repeater MIB; Ethernet
Interface MIB
Services
Services
Services
Services
3-year, 4-hour onsite, 13x5 coverage for hardware (UE247E)
3-year, 4-hour onsite, 24x7 coverage for hardware (UE248E)
3-year, 4-hour onsite, 24x7 coverage for hardware, 24x7 software phone
support (UE249E)
QuickSpecs
HP ProCurve Switch 4200vl Series
HP ProCurve Switch 4200vl Series
HP ProCurve Switch 4200vl Series
HP ProCurve Switch 4200vl Series
Technical Specifications
DA - 12435   Worldwide — Version 8 — August 20, 2009