Cabinet Dimensions
Cabinet opening dimensions shown are for 25" (64.0 cm) 
countertop depth, 24" (61.0 cm) base cabinet depth and 
36" (91.4 cm) countertop height. 
If the cabinet depth is greater than 24" (61.0 cm), the oven frame 
must extend beyond cabinet fronts by ½" (13.0 mm) minimum.
IMPORTANT: If installing a range hood or microwave hood 
combination above the range, follow the range hood or 
microwave hood combination installation instructions for 
dimensional clearances above the cooktop surface.
NOTE: 24" (61.0 cm) minimum when bottom of wood or metal 
cabinet is covered by not less than ¼" (0.64 cm) flame retardant 
millboard covered with not less than No. 28 MSG sheet steel, 
0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm) aluminum or 
0.020" (0.5 mm) copper. 
30" (76.2 cm) minimum clearance between the top of the cooking 
platform and the bottom of an uncovered wood or metal cabinet. 
Electrical Requirements 
If codes permit and a separate ground wire is used, it is 
recommended that a qualified electrical installer determine that 
the ground path is adequate and wire gauge is in accordance 
with local codes.
Do not use an extension cord.
Be sure that the electrical connection and wire size are adequate 
and in conformance with the National Electrical Code, ANSI/
NFPA 70-latest edition and all local codes and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
One Batterymarch Park
Quincy, MA 02269
WARNING: Improper connection of the equipment-grounding 
conductor can result in a risk of electric shock. Check with a 
qualified electrician or service technician if you are in doubt as to 
whether the appliance is properly grounded. Do not modify the 
power supply cord plug. If it will not fit the outlet, have a proper 
outlet installed by a qualified electrician.
Electrical Connection
To properly install your range, you must determine the type of 
electrical connection you will be using and follow the instructions 
provided for it here.
Range must be connected to the proper electrical voltage 
and frequency as specified on the model/serial number rating 
plate. The model/serial number rating plate is located under 
the front left burner bowl. Refer to the figure in the “Location 
Requirements” section.
This range is manufactured with the neutral terminal 
connected to the cabinet. Use a 3-wire UL listed, 40- or 50-
amp power supply cord (pigtail) (see Range Rating chart 
below). If local codes do not permit ground through the 
neutral, use a 4-wire power supply cord rated at 250 volts, 
40 or 50 amps and investigated for use with ranges.
*The NEC calculated load is less than the total connected load 
listed on the model/serial rating plate.
**If connecting to a 50-amp circuit, use a 50-amp rated cord with 
kit. For 50-amp rated cord kits, use kits that specify use with a 
nominal 1
³⁄₈" (34.93 mm) diameter connection opening.
A circuit breaker is recommended.
The range can be connected directly to the circuit breaker 
box (or fused disconnect) through flexible or nonmetallic 
sheathed, copper or aluminum cable. See “Electrical 
Connection.”
Allow 2 to 3 ft (61.0 cm to 91.4 cm) of slack in the line so that 
the range can be moved if servicing is ever necessary.
A UL listed conduit connector must be provided at each end 
of the power supply cable (at the range and at the junction 
box).
Wire sizes and connections must conform with the rating of 
the range (40 amps).
The wiring diagram is located on the underside of the storage 
drawer or below the warming drawer in a clear plastic bag.
A. 18" (45.7 cm) min. clearance 
upper side cabinet to 
countertop
B. 13" (33.0 cm) max. upper 
cabinet depth
C. 20" (50.8 cm) min. cabinet 
opening width
D. 20
¹⁄₈
" (51.1 cm) opening width
E. 5" (12.7 cm) min. countertop 
space to side wall or other 
combustible material
F. For minimum clearance to top 
of cooktop, see NOTE.
G. Wall receptacle - 8" (20.3 cm) 
from either cabinet,
H. 5½" (14.0 cm) max. from floor.
Locate 120/240-volt 
receptacle in shaded area. 
A
B
C
D
E
F
G
H
G
Range Rating*
Specified Rating of 
Power Supply Cord Kit 
and Circuit Protection
120/240 Volts
120/208 Volts
Amps
8.0 - 16.5 KW
16.6 - 22.5 KW
6.0 - 12.5 KW
12.6 - 18.5 KW
40 or 50**
50