GMX 200 Environmental Qualification Form 
005-00315-20 
Page 1 of 2 
  Rev 1 
G M X   2 0 0   M u l t i - F u n c t i o n   D i s p l a y  
  E n v i r o n m e n t a l   Q u a l i f i c a t i o n   F o r m  
 
 
Nomenclature:            GMX 200 Multi-Function Display 
 
Type/Model/Part Number:   
     GMX 200 Standard 
   
 Garmin Part Number 010-00483-(), which includes 011-01271-() 
     GMX 200 I/O Traffic     
 Garmin Part Number 010-00571-(), which includes 011-01465-() 
     GMX 200 I/O Radar/TAWS 
 Garmin Part Number 010-00486-(), which includes 011-01466-() 
     GMX 200 I/O Radar/Traffic 
 Garmin Part Number 010-00487-(), which includes 011-01467-() 
 
 
 
 
TSO Number:  TSO-C63c   
 
Airborne Weather and Ground Mapping Pulsed Radar 
 
                TSO-C110a 
 
Airborne Passive Thunderstorm Equipment 
 
                TSO-C113  
 
Multipurpose Electronic Displays 
 
                TSO-C118  
 
Traffic Alert and Collision Avoidance System (TCAS 1) 
 
                TSO-C147  
 
Traffic Advisory System (TAS) Airborne Equipment 
 
                 
 
 
Manufacturer's Specification And/Or Other Applicable Specification: 
 
  
004-00221-00 
Manufacturer: 
 
 
Garmin Ltd. or its subsidiaries 
Address: 
 
 
1200 East 151
st
 Street 
  
Olathe, 
Kansas 
66062 
  
U.S.A. 
Date Tested: 
 The GMX 200 has been tested to the following environmental categories per procedures defined in RTCA/DO- 
160D. Tests were conducted from February 2006 to June 2006 using the original 1997 revision of DO-160D, 
(except where credit was claimed for previous testing to equivalent levels, refer to Garmin document 005-00315-19 
for details). 
 
 
RTCA D O - 1 6 0 D  Conditions 
D O - 1 6 0 D  
Section 
 
D e s c r i p t i o n   o f   C o n d u c t e d   T e s t s  
Temperature and Altitude 
Low Temperature 
High Temperature 
In-Flight Loss of Cooling 
Altitude 
Decompression 
Overpressure 
4.0 
4.5.1 
4.5.2 & 4.5.3 
4.5.4 
4.6.1 
4.6.2 
4.6.3 
Equipment tested to Categories A1F1 
 
 
Equipment Tested to Category Y 
 
 
 
Equipment was operating during test. 
Temperature Variation 
 
5.0
 
Equipment tested to Category C 
Humidity 6.0 
 
Equipment tested to Category A