Hussmann crfd Scheda Tecnica

Pagina di 20
20 
 
1 of 20 
CRFD 
Technical Data Sheet 
 
 
Rev A
Specialty Products 
CRFD 
      
 
 
 
 
 
 
 
 
 
 
 
 
We reserve the right to change or revise specifications and 
product design in connection with any feature of our 
products.  Such changes do not entitle the buyer to 
corresponding changes, improvements, additions or 
replacements for equipment previously sold or shipped. 
REFRIGERATION DATA 
Note: This data is based on store temperature and 
humidity that does not exceed 75F and 55% R.H.
 
 
 
 
 
 
Discharge Air (F) 
35 
 
 
Evaporator (F) 
25 
 
Note: Not recommended to control temp by regulating 
coil temp allow t-stat to cycle and control temp. 
 
½ Case 
 
 
 
 
Btu/hr/total 
Parallel   
    10,500 
   
Conventional             12,075 
 
Full Case 
 
 
 
 
Btu/hr/total 
Parallel   
    21,000 
   
Conventional             24,150 
 
 
 
*For all refrigeration equipment other than Hussmann, 
use conventional Btu values. 
 
DEFROST DATA 
Frequency Hrs  
 
 
OFFTIME  
Temp Term °F 
54 
Failsafe Minutes  
24 
          
 
ELECTRIC or GAS     Not Recommended 
 
 
 
PHYSICAL DATA 
Merchandiser Drip Pipe (in.) 
1 ½* 
Merchandiser Liquid Line (in.) 
3/8* 
Merchandiser Suction Line (in.) 
5/8* 
 
Estimated Charge (lb)*** 
4ft 1.2 
5ft 1.5 
6ft 1.8 
 
*Dependent on case length and refrigerant type. 
 
*** This is an average for all refrigerants types.  Actual 
refrigerant charge may vary by approximately half a 
pound. 
GLYCOL REQUIREMENTS 
   
 
 
 
  GPM           PSI 
 
 
 NA 
 
NA   
 
 
  NA         
NA 
 
 
 
  NA         
NA 
 
  
   
 
 CUL Listed