Hussmann hgl-1bs Istruzione Sull'Installazione
Page 13
3. Cabinet location too warm 3. Relocate
4. Too much refrigerant
4. Change drier, evacuate, and
recharge
recharge
5. Low voltage. Compressor
cycling on overload
cycling on overload
5. Check power
6. Condenser dirty
6. Clean
Compressor runs continuously.
Product too cold
Product too cold
1. Defective control
1. Replace
2. Control feeder tube not in
positive contract
positive contract
2. Assure proper contract
3. Short on refrigerant
3. Leak check, change drier,
evacuate, and recharge
evacuate, and recharge
Compressor will not start, no
noise
noise
1. Blown fuse or breaker
1. Replace fuse or reset
breaker
breaker
2. Defective or broken wiring 2. Repair or replace
3. Defective overload
3. Replace
4. Defective temperature con-
trol
trol
4. Replace
5. Power disconnected
5. Check service cord or wir-
ing connections
ing connections
Compressor will not start, cuts
out on overload
out on overload
1. Low voltage
1. Contact electrician
2. Defective compressor
2. Replace
3. Defective relay
3. Replace
4. Restriction or moisture
4. Leak check, replace drier,
evacuate and recharge
evacuate and recharge
5. Inadequate air over con-
denser
denser
5. Clean condenser